Table 3. Echocardiographic parameters before and after Cardioband implantation.

Pat. TR grade TR-VC, mm TR coaptation deficit, mm TV ring D, mm TVA anteroseptal D, mm RV basal D, mm TAPSE Sys. hepatico-venous reflux
Before After Before After Before After Before After Before After Before After Before After Before After
1 5 2 9 3 9 0 57 39 55 48 66 48 23 8 Yes No
2 5 2 22 3 11 0 39 29 48 34 46 34 20 19 Yes No
3 5 3 13 10 18 5 27 26 41 37 37 37 17 15 Yes No
4 3 1 8 3 0 0 33 27 41 43 40 43 17 17 Yes No
5 5 3 22 11 13 3 41 28 49 38 55 38 16 13 Yes Yes
6 5 2 9 5 6 4 50 28 41 52 52 52 14 21 Yes Yes
7 5 3 16 11 5 0 49 34 45 54 58 54 12 12 Yes Yes
8 3 2 9 5 0 0 38 33 36 40 42 40 21 24 Yes No
9 5 3 22 7 11 0 44 34 46 57 57 57 18 ø Yes No
10 4 1 14 3 Ø 0 32 24 38 41 36 41 19 15 Yes No
11 5 2 13 5 Ø Ø 50 39 55 44 64 44 22 21 Yes No
12 5 2 19 Ø 4 Ø 34 Ø 44 44 47 44 18 10 Yes No
13 3 1 8 4 2 0 41 30 34 37 43 37 16 10 Yes No
14 5 1 13 3 12 0 47 38 42 34 45 34 19 10 Yes No
Average 71.4% 5 7.2% 4 21.4% 3 21.4% 3 43.0% 2 28.6% 1 14±6 6±3 7±6 2±2 42±9 30±4 44±7 34±7 49±10 44±7 18±3 15±5 100% Yes 21.4% Yes 78.6% No
p<0.001 p<0.001 p=0.003 p<0.001 p<0.001 p=0.014 p=0.128 p<0.001
D: diameter; RV: right ventricular; Sys: systolic; TAPSE: tricuspid annular plane systolic excursion; TR: tricuspid regurgitation; TV: tricuspid valve; TVA: tricuspid valve annulus; VC: vena contracta