Skip to main content
. 2022 Dec 16;4(12):e0814. doi: 10.1097/CCE.0000000000000814

Table 1.

Performance Metrics of the Algorithm With Various Modifications, Including Adjustment of the Delta Factor and the Addition of Upper and Lower Limits

Delta No Upper and Lower Thresholds Lower (> 30 mm Hg) and Upper (< 200 mm Hg) Thresholds
Sensitivity (%) Specificity (%) MCC Sensitivity (%) Specificity (%) MCC
1× deltas 92.31 98.75 0.39 97.48 98.59 0.40
0.4× deltas 94.96a 98.02a 0.34 97.48 98.02 0.35
1.3× deltas 93.28b 98.68b 0.40 97.48a 98.68a 0.41
2× deltas 91.60 98.72 0.40 96.64b 98.72b 0.42
4× deltas 86.55 98.72 0.37 95.80 98.72 0.41

MCC = Matthew correlation coefficient.

aSensitivity and specificity optimized.