Example of calculation of relative fold enrichment

Sample name Target name Reporter # Adjusted Cт to negative control # # Adjustment to input Fold enrichment Average fold enrichment
E2F6 IP Zcwpw1-a SYBR 23.6 6.9 7.1 137.4 158.1
E2F6 IP Zcwpw1-a SYBR 23.3 7.2 7.5 178.8
E2F6 IP Zcwpw1-b SYBR 24.0 6.5 7.6 196.5 175.0
E2F6 IP Zcwpw1-b SYBR 24.4 6.1 7.3 153.6
E2F6 IP Rab8a SYBR 26.9 3.6 6.9 116.6 114.6
E2F6 IP Rab8a SYBR 27.0 3.5 6.8 112.6
E2F6 IP RNF130 SYBR 24.9 5.7 7.0 125.2 121.4
E2F6 IP RNF130 SYBR 24.9 5.6 6.9 117.6
E2F6 IP Neg control SYBR 30.9 30.5 -0.4 -0.4 0.8 1.0
E2F6 IP Neg control SYBR 30.1 0.4 0.4 1.3
Input Zcwpw1-a SYBR 25.0 -0.5 -0.2
Input Zcwpw1-a SYBR 24.5 0.0
Input Zcwpw1-b SYBR 25.5 -1.0 -1.1
Input Zcwpw1-b SYBR 25.8 -1.3
Input Rab8a SYBR 27.8 -3.3 -3.3
Input Rab8a SYBR 27.8 -3.3
Input RNF130 SYBR 25.9 -1.4 -1.3
Input RNF130 SYBR 25.7 -1.2
Input Neg control SYBR 24.6 24.5 -0.1 0.0
Input Neg control SYBR 24.4 0.1
# Average of negative control
# # Average of input