Skip to main content
. 2022 Aug 13;4(12):1053–1059. doi: 10.1016/j.cjco.2022.08.005

Table 2.

Outcomes of the cohorts before vs after implementation of the Vancouver 3M (multidisciplinary, multimodality, but minimalist) clinical pathway

Outcome Pre-implementation (n = 126) Post-implementation (n = 165)
30-day mortality 7 (5.6) 1 (0.6)
30-day rehospitalizations 36/119 (30) 11/164 (6.7)
In-hospital mortality 7 (5.5) 1 (0.6)
Requirement of second THV implantation 4 (3.2) 0 (0)
All vascular complications 14 (11) 3 (1.8)
Major vascular complications 3 (2.4) 0 (0)
PPM implantation 14/107 (13) 13/148 (8.8)
Post TAVI length of stay, d, median (IQR) 5 (2–6) 1 (1–3)

Values are n (%), unless otherwise specified.

IQR, interquartile range; PPM, permanent pacemaker; TAVI, transcatheter aortic valve implantation; THV, transcatheter heart valve.