Table 2.
Summary of TENG parameters.
Date | Positions | Sizes [cm2] | Materials | Energy Sources | Outputs | Applications | Working Modes |
---|---|---|---|---|---|---|---|
2022 [54] | Pulse | 5 × 5 | Cu, Silicone rubber | Pulse vibration | 0.89 V/kPa | Pulse monitoring | Contact-separation |
2021 [55] | Pulse | None | FEP, PA, Cu, PET | Pulse vibration | 10.29 nA/kPa | Pulse monitoring | Contact-separation |
2022 [56] | Pulse | 1.8 × 1.6 | PTFE, Cu | Pulse vibration | 1.65 V/kPa | Pulse monitoring | Contact-separation |
2022 [60] | Nose | 5 × 2 | MXene | Respiratory drive | 27 μW | Respiratory monitoring | Contact-separation |
2022 [62] | Solution | 2 × 0.5 | ITO | Vibration | 165 V | Bacterial detection | Contact-separation |
2021 [63] | Nose | 4 × 4 | Polyacrylonitrile, Polyamide 66 | Respiratory drive | 420 v | OSAHS diagnostics | Contact-separation |
2021 [64] | Wearable | 31 × 3 | Catechol, Chitosan, Diatom | Movement | 29.8 mW/m2 | Parkinson diagnosis | Contact-separation |
2021 [65] | Wearable | 4 × 3.5 | Ecoflex, Al | Movement | 2 V | Parkinson diagnosis | Contact-separation |