Microfluidization |
1/99–50/50 (10/90 is
the most common) |
0.1–10% (2% is the most
common) |
High-speed blender for 1–5 min using 6000–24000 rpm (there are works that apply directly
microfluidizer75,76,139,149,150) |
50–150 MPa for 1–8 cycles (4 is the most common) |
(2), (67), (143), (144) ,149−156, (71), (157−161)(74−76), (78), (79), (139), (142) |
High-Pressure Homogenization |
5/95–30/70 (10/90 is
the most common) |
0.1–5% (1% is the most
common) |
High-speed blender for 1–5 min using 5000–15000 rpm |
20–170 MPa
for 1–10 cycles (4 is the most
common) |
(15), (16), (141), (162−166), (17), (20), (23), (68), (69), (88), (94), (140) |
Ultrasonication |
3/97–30/70 (10/90 is
the most common) |
0.5–10% (2% is the most
common) |
High-speed blender for 1–5 min using 6000–24000 rpm (there are works that apply directly
sonication70,167,168) |
Bath and Probe sonication, 10–600 W, 2–50 min, 5–30 s pulse on/off |
(13), (70), (90), (95), (167−172) |