Table 1. List of Membranes, Feed Streams, and Tested Conditions.
| membrane | conditions
(agitation 200 rpm) |
||
|---|---|---|---|
| IL concentration | pressure | temperature | |
| MP005-MF, PT-UF, GH-UF, DL-NF, TS80-NF, NF270-NF, BW30LE-NF, UTC-73A-RO | 1 wt % [mTBDH][OAc] | 10 bars | 298.2 K |
| 1 wt % [mTBNH][OAc] | 10 bars | 298.2 K | |
| BW30LE-RO, NF270-NF | 1 wt % [mTBDH][OAc] | 10–50 bar | 298.2 K |
| 1 wt % [mTBNH][OAc] | 10–50 bar | 298.2 K | |
| 1, 5, 10, 15, 20 wt % [mTBDH][OAc] | 40 bars | 298.2 K | |
| 1, 5, 10, 15, 20 wt % [mTBNH][OAc] | 40 bars | 298.2 K | |
| 1, 15 wt % [mTBDH][OAc] | 40 bars | 298.2/313.2 K | |
| 1, 15 wt % [mTBNH][OAc] | 40 bars | 298.2/313.2 K | |