Skip to main content
. 2022 Nov 23;13(12):2051. doi: 10.3390/mi13122051

Table 6.

Efficient resonant action pressure sensors performance comparison.

Basic Accuracy Output Conformity Error Hysteresis Error Repeatability Error Sensitivity (Hz/kPa) Range (kPa) Operating Temperature (°C) Reference
n/a 0.021 n/a n/a 7.35 <250 −40 to +60 [103]
n/a 0.021 n/a n/a 20 <180 −20 to +80 [108]
n/a n/a n/a n/a 45 <110 n/a [109]
0.045 0.0102 0.0045 0.044 n/a <400 −20 to +60 [107]
0.064 0.0148 0.0525 0.0315 36.58 <100 −20 to +60 [107]