Skip to main content
letter
. 2022 Dec 23;17:563. doi: 10.1186/s13018-022-03462-1

Table 3.

Shortening height of “point-to-face” and “face-to-face” with different varus angles

Osteotomy method Shortening length at different varus angles (mm)
10° 15° 20° 25°
“point-to-face” 2 4 6 8 10
t' 2.11 4.21 6.27 8.28 10.25
“face-to-face” 4.11 8.21 12.27 16.28 20.25