Skip to main content
. 2022 Dec 24;137:104275. doi: 10.1016/j.jbi.2022.104275

Fig. 3.

Fig. 3

Characterizing two patient#1 pressure data sequences with 12 parameters ϕ12. Data (A and C, dashed black) are well-estimated by inference model estimates (blue) in continuous time on overlapping 1.2 s analysis windows. Tabulating data (B and D, black) and mean parameter estimates (blue, with inter-quartile range shown) in cyclic breath time compares the characterization (red) of each sequence with the data. Mean parameter vectors of the two sequences, which have significant distributional differences, are depicted over a normalized breath duration (E). (For interpretation of the references to color in this figure legend, the reader is referred to the web version of this article.)