Skip to main content
. 2022 Dec 24;137:104275. doi: 10.1016/j.jbi.2022.104275

Table D.5.

RMS errors (RMSE) of estimates to data for various resolutions and the single compartment model (Eqn(1)), with lowest error among proposed static model characterizations is indicated in bold. Large errors in volume of compartment model estimation result from persistent differences in phase.

MODEL ϕ12 ϕ18 ϕ24 ϕ30 Eqn(1)
Pressure (cm H2O)
p#3 seq1 1.03 0.80 0.60 1.11 0.65
p#3 seq2 0.70 0.66 0.63 0.62 1.43
p#4 2.61 2.27 2.06 1.87 4.71
p#5 0.63 0.62 0.63 0.63 3.32
p#6 1.50 1.51 1.57 1.97 3.46

Volume (ml)
p#3 seq1 16.92 12.11 10.07 9.70 23.81
p#3 seq2 56.55 55.83 55.80 55.60 349.77
p#4 29.31 29.09 29.59 31.37 58.43
p#5 44.02 43.76 43.71 43.70 230.45
p#6 148.32 148.73 155.00 166.66 262.49