. 2022 Dec 6;10(34):12594–12604. doi: 10.12998/wjcc.v10.i34.12594

Table 1.

Basic characteristics of the studies included

Ref.
Country
Sample size
Age (range, yr)
Diagnosis
Research type
Methods
TP
FP
FN
TN
Singhal and Danks[16], 2022 Australia 68 62 (21-87) TN Retrospective 3D TOF MRA + 3D CISS 50 3 7 8
Jia et al[17], 2016 China 95 49.2 HFS Prospective 3D TOF MRA + 3D CISS 94 0 0 1
Xie et al[9], 2014 China 90 56.8 (31-76) TN Retrospective 3D TOF MRA + 3D CISS 81 0 6 3
Shi et al[18], 2022 China 40 49.6 (24-66) HFS Retrospective 3D TOF MRA + 3D FIESTA 35 0 4 1
Jiang et al[10], 2022 China 49 53.1 (30-77) TN Prospective 3D TOF MRA + 3D FIESTA 48 0 0 1
Wei et al[11], 2020 China 146 56 (32-83) TN Retrospective 3D TOF MRA + 3D FIESTA 129 0 14 3
Guo et al[19], 2018 China 36 55.8 (31-80) TN Retrospective 3D TOF MRA + 3D FIESTA 33 0 1 2
31 51.5 (39-64) HFS 3D TOF MRA + 3D FIESTA 28 1 1 1
Liu et al[12], 2016 China 52 53.7 (35-72) TN Prospective 3D TOF MRA + 3D FIESTA 44 0 5 3
Zeng et al[13], 2013 China 37 56.3 (22-81) TN Prospective 3D TOF MRA + 3D FIESTA 35 0 1 1
Xia et al[20], 2015 China 106 51.9 (26-81) TN/HFS Retrospective 3D TOF MRA + 3D SPACE 97 0 2 7
Müller et al[14], 2020 Germany 38 59.63 ± 13.56 TN Retrospective 3D TOF MRA + bSSFP/FSE 31 0 0 7
Vergani et al[15], 2011 United Kingdom 67 59.8 (32-84) TN Retrospective 3D TOF MRA + 3D TSE DRIVE 60 1 3 3

CISS: Constructive Interference Steady State; FIESTA: Fast Imaging Employing Steady-state Acquisition; SPACE: Sampling Perfection with Application optimized Contrast using different flip angle Evolution; bSSFP: Balanced Steady State Free Precession; FSE: Fast spin echo; TSE DRIVE: Turbo Spin-Echo Driven Equilibrium; TN: Trigeminal neuralgia; HFS: Hemifacial spasm; TP: True positive; FP False positive; FN: False negative; TN: True negative; 3D TOF MRA: Three-dimensional time-of-flight magnetic resonance angiography.