Abstract
Background
Clinical laboratory errors have a great impact on patient safety and treatment. Although specimen rejections result in longer turnaround times and increased health-care costs, different studies present inconsistent findings. Therefore, the study aimed to determine the pooled prevalence of blood specimen rejection in clinical laboratory.
Methods
Electronic databases including MEDLINE, PubMed, EMBASE, HINARI, Cochrane Library, Google Scholar, and Science Direct were comprehensively searched. Articles were screened and the data extracted independently by authors. Publication bias was checked by funnel-plots and Egger's statistical test. Pooled prevalence was estimated using a random-effects model. The I2 statistical test were performed to assess heterogeneity. The possible sources of heterogeneity were analyzed through subgroup and sensitivity analysis.
Results
Total of 26 articles with 16,118,499 blood sample requests were included in the meta-analysis. The pooled prevalence of blood specimen rejection in the clinical laboratory was 1.99% (95% CI: 1.73, 2.25). Subgroup analysis showed that, the highest prevalence of specimen rejection was observed in Asia [2.82% (95%CI: 2.21, 3.43)] and lowest in America [0.55% (95%CI: 0.27, 0.82)]. The leading cause of blood specimen rejection in clinical laboratories were clotted specimen (32.23% (95%CI: 21.02, 43.43)), hemolysis (22.87% (95%CI: 16.72, 29.02)), insufficient volume (22.81% (95%CI: 16.75, 28.87)), and labelling errors (7.31% (95%CI: 6.12, 8.58)).
Conclusion
The pooled prevalence of blood specimen rejection rate is relatively high especially in developing regions. Therefore, proper training for specimen collectors, compliance with good laboratory practices specific to specimen collection, transportation, and preparation is required to reduce the rejection rate.
Keywords: Specimen rejection, Blood specimen, Clinical laboratory, Meta-analysis
Abbreviations: TAT:, Turnaround time; CI:, Confidence interval; RBC:, Red blood cell; USA:, United States of America
Highlights
-
•
The overall blood specimen rejection in clinical laboratory was 1.99% (95% CI: 1.73, 2.25).
-
•
Clotted specimen, hemolysis, insufficient volume, and labelling errors were the major cause of blood specimen rejection.
-
•
Proper training for specimen collectors and compliance with good laboratory practices are required to reduce the rejection rate.
1. Introduction
Laboratory medicine plays a vital role in everyday clinical practice as well as in the long term follow-up of patients [1]. The dependence of patient management on laboratory data highlights the need for ensuring the quality of these services [2]. Laboratory testing is generally classified into pre-analytical, analytical and post-analytical phases [3]. The pre-analytical phase encompasses stages such as test selection, patient identification, sample collection, sample handling, sorting out, pipetting, and centrifugation [1,[4], [5], [6]]. Approximately 70% of laboratory errors originate in the pre-analytical phase [7]. Pre-analytical issues including missing patient's identification, inappropriate containers, missing samples and labelling errors have been a major challenges faced by the laboratory professionals [8,9].
Specimen collection is one of the initial pre-analytical processes that ensure accurate, reliable and timely results for patients [10]. Specimens are rejected by the laboratory if they do not meet predefined technical requirements for each specific analyte [11]. When samples are rejected, it is important to inform authorized personnel that the sample is unsuitable for testing, and request another sample to be collected [10]. The rejection rate reflects the pre-analytical process of the laboratory path of workflow, which includes sample collection and transport [11].
The main reason for rejection is insufficient specimen collection by the paramedical workers [12]. Some of the pre-analytical errors in the laboratory that lead to sample rejection include labeling errors, no test stated on the request form, illegible requests, clotting, inadequate blood volume, improper sample tube, hemolysis, and incorrect temperature during sample transport or storage [1]. Rejection of specimens has major clinical consequences on the patient management. Re-drawing of blood from a patient is uncomfortable, and complications such as hematoma and iatrogenic anemia are potential risks [13]. Another well-known consequence of specimen rejection is a delay in the performance and reporting of the results of the ordered tests [14]. Reduction of risk associated with the pre-analytical phase is critical for cost effectiveness, total quality improvement and customer satisfaction [15].
Since majority of laboratory errors occurred during the pre-analytical phases, the current systematic review and meta-analysis sought to determine the overall blood specimen rejection rate in the clinical laboratory as well as the causes of specimen rejection in the pre-analytical phase in the global setting.
2. Methods
2.1. Study design and search strategy
A systematic review and meta-analysis of published studies were conducted to assess the pooled prevalence of blood specimen rejection in clinical laboratory. In conducting this study, Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines [16] were strictly followed (Supplemental Table 1). The studies were identified by conducting an online search of the databases of MEDLINE, PubMed, EMBASE, HINARI, Cochrane Library, Google Scholar, and Science Direct. The search was done using the following search terms including but not limited to specimen rejection, blood specimen rejection, blood sample rejection, laboratory rejection, sample rejection, analytical error, and clinical laboratory. The search terms were used separately and in combination using Boolean operators like “OR” or “AND”. The search strategies for PubMed were ((((((Specimen rejection[Title/Abstract]) OR (Blood specimen rejection[Title/Abstract])) OR (Sample rejection[Title/Abstract])) OR (Blood sample rejection[Title/Abstract])) OR (laboratory rejection[Title/Abstract])) OR (pre-analytical error[Title/Abstract])) AND (((((((Clinical laboratory[Title/Abstract]) OR (Hematology laboratory[Title/Abstract])) OR (Biochemistry laboratory[Title/Abstract])) OR (Clinical chemistry laboratory[Title/Abstract])) OR (Immunology laboratory[Title/Abstract])) OR (Serology laboratory[Title/Abstract])) OR (Molecular biology laboratory[Title/Abstract])). Additional publications were discovered by checking the reference lists of previously recognized articles and conducting a manual search. All published articles before February 30, 2021 were included in this review.
2.2. Eligibility criteria
All prospective and retrospective cohort studies and cross-sectional studies published before to February 30, 2021, that documented the prevalence or rate of blood specimen rejection in clinical biochemistry, hematology and immunology laboratories were included. Studies which report the rate of specimen rejections other than blood specimens and histopathology samples were excluded. Review articles, case-report and case-series studies and duplicated articles published from the same dataset were excluded.
3. Outcome of interest
This review considered studies that include rate of blood specimen rejection in clinical laboratory as an outcome. Specimen rejections are defined as specimens that do not fulfill specimen acceptance criteria of the test(s) requested [13]. The second outcome of interest were determining the major causes of specimen rejection. Samples are rejected on the basis of preset rejection criteria as follows: unlabeled and mislabeled specimen, specimen without request form, wrong choice of sample collection/transportation tube, wrong label/wrong medical record number, insufficient sample, hemolyzed sample, clotted specimens, improper sample transport, and delayed specimen in transit making results invalid [9].
3.1. Data extraction and quality assessment
All the searched articles were imported into EndNote version X7 software and duplicate articles were removed. Two authors (SG and TA) independently reviewed titles and abstract of included studies and reviewed full-text of selected articles according to the eligibility criteria. Moreover, discrepancies between authors were resolved through discussion and consulting a third author (MM). Data extractions were conducted by two authors (SG and MA) independently by using an organized format on Microsoft Excel Spreadsheet. The following data were extracted for analysis: author's name, publication year, laboratory section, sample size, rate or percentage of rejection, duration of study period and causes of rejection. Quality assessment was conducted by two experts using Joana Brigg's Institute (JBI) critical appraisal checklist for simple prevalence [17]. The checklist consists of 9 items such as [1]: was the sample frame appropriate to address the target population? [2] Were study participants sampled appropriately? [3] Was the sample size adequate? [4] Were the study subjects and the setting described in detail? [5] Was the data analysis conducted with sufficient coverage of the identified sample? [6] Were valid methods used for the identification of the condition? [7] Was the condition measured in a standard, reliable way for all participants? [8] Was there an appropriate statistical analysis? [9] Was the response rate adequate? Based on these, individual studies were assigned a score in line with the review objectives. The responses were scored 0 for “Not appropriate and not reported” and 1 for “Yes”. Total scores ranged between 0 and 9. Studies fulfilling 50% of quality assessment were included for analysis (Supplemental Table 2).
3.2. Publication bias and heterogeneity
The existence of heterogeneity of the included studies was assessed using I2 statistics and its corresponding p-value [18]. A value of 25%, 50%, and 75% was used to declare the heterogeneity test as low, medium and high heterogeneity, respectively. Random effect model was used for results with statistically significant heterogeneity. Funnel plots analysis and Egger weighted regression tests were done to detect publication bias. A p-value <0.05 in Egger's test was considered as evidence of statistically significant publication bias [19,20].
3.3. Synthesis of result and statistical analysis
The data were entered using Microsoft Excel sheet. The meta-analysis was conducted using STATA version 11 software. Forest plots were used to present the pooled effect size and weight of each recruited study with 95% CI to show a graphic summary of the data. The estimated pooled prevalence was computed with 95% CI. Subgroup analysis and sensitivity was done to assess the potential source of heterogeneity.
4. Results
4.1. Search results
We retrieved 2343 possible articles regarding the rate of blood specimen rejection as identified in PubMed, Google Scholar, Scopus, and Science Direct. After duplicate removal, 1408 articles were screened by their title and abstract of which 1359 were excluded. Of the 49 potential full text articles assessed for eligibility, 23 were excluded for major reasons (Fig. 1).
Fig. 1.
Flow chart describing selection of studies on the prevalence of blood specimen rejection.
4.2. Description of included studies
In the current study 26 studies published from 2009 to 2020 across the globe were included to estimate the pooled prevalence of blood specimen rejection rate. All of the included studies were carried out in the hematology, clinical chemistry and immunology/serology laboratory sections. The minimum sample size was 3259 specimens in a study conducted in Ethiopia [21] while the highest sample size was 10,181,036 specimens, in China [22]. Overall, this meta-analysis included a total of 16,118,499 blood specimens. The highest rate of blood specimen rejection was 10.58% in the emergency unit of Sir T General Hospital and Govt. Medical College, Bhavnagar, India [23]. The majority of the laboratories included in these studies serve patients from both inpatient and outpatient settings departments. Furthermore, the majority of the studies retrieved data from the laboratory information system retrospectively. Ten countries were represented in this review. Four of the studies were from Africa [13,15,21,24], 5 from Europe [6,[25], [26], [27], [28]], 13 from Asia [3,9,22,23,[29], [30], [31], [32], [33], [34], [35], [36], [37]] and 4 from America [7,[38], [39], [40]] (Supplemental Table 3).
4.3. Prevalence of blood specimen rejection
A total of 16,118,499 blood specimens in 26 studies were used to estimate the pooled prevalence of blood specimen rejection in clinical laboratories. Of the total blood specimen, 106,984 of them were rejected. The minimum prevalence of specimen rejection rate were 0.11% reported from China [22] while the maximum were 10.58% in New Delhi India from emergency unit of the hospital [23]. In random-effect model analysis, the pooled prevalence of blood specimen rejection in clinical laboratories was 1.99% (95% CI: 1.73, 2.25). A high level of heterogeneity was observed across the included studies (I2 = 100%, p < 0.001) (Fig. 2).
Fig. 2.
Forest plot showing the pooled prevalence of blood specimen rejection.
4.4. Subgroup analysis
In order to minimize heterogeneity, the pooled prevalence of blood specimen rejection in clinical laboratories, sub-group analysis was done based on WHO-region of the study where conducted. The result showed that the pooled prevalence of blood specimen rejection rate was high in the South-East Asian region [3.19% (95%CI: 2.03, 4.35)], and African region [1.79% (95%CI: 1.43, 2.15)]. However, the pooled prevalence of blood specimen rejection was low in European region [1.32% (95%CI: 0.64, 2.00)] and regions of the Americas [0.55% (95%CI: 0.27, 0.82)]. There was a significant level of heterogeneity between all of the included studies (P ≤ 0.001). Furthermore, subgroup analysis by each laboratory section revealed that, the clinical chemistry section (3.05% (95%: 1.74, 4.35) demonstrated the highest number of blood specimen rejection (Table 1).
Table 1.
Subgroup analysis of the prevalence of blood specimen rejection by region and laboratory section in clinical laboratories globally.
| Subgroup |
Number of studies | Prevalence (95% CI) | I2 | P value |
|---|---|---|---|---|
| WHO- region | ||||
| South-East Asian | 11 | 3.19 (2.03, 4.35) | 100% | ≤0.001 |
| African | 4 | 1.79(1.43, 2.15) | 93.9% | ≤0.001 |
| European | 7 | 1.32(0.64, 2.00) | 100% | ≤0.001 |
| American | 4 | 0.55(0.27, 0.82) | 99.8% | ≤0.001 |
| Eastern-Mediterranean | 1 | 1.48(1.41–1.55) | – | – |
| Western-Pacific | 1 | 0.11(0.11–0.11) | – | – |
| Laboratory section | ||||
| Clinical chemistry | 7 | 3.05(1.74, 4.35) | 100% | ≤0.001 |
| Hematology | 10 | 1.22(0.91, 1.53) | 100% | ≤0.001 |
| Hematology and clinical chemistry | 8 | 2.45(1.73, 3.17) | 100% | ≤0.001 |
| Biochemistry, immunology and hematology | 2 | 0.60(0.55, 0.65) | 62.5% | 0.103 |
| Biochemistry and immunology | 1 | 1.70(1.57, 1.83) | – | – |
| Combined | 28 | 1.99(1.73, 2.25) | 100% | ≤0.001 |
Abbreviation: CI; Confidence interval.
4.5. Sensitivity analysis
Due to the high heterogeneity of results, a sensitivity analysis was done to evaluate the effect of each study on the pooled estimates by omitting each study stepwise. The analysis revealed that omitted studies have no significant effect on the pooled prevalence of blood specimen rejection in clinical laboratories (Fig. 3).
Fig. 3.
Sensitivity analysis of studies included to estimate pooled prevalence of blood specimen rejection.
4.6. Publication bias
The included studies were assessed visually by funnel plot for potential publication bias. The asymmetric funnel plot indicated the presence of publication bias since 100% of the studies fell out of the triangular region (Fig. 4). Besides, the result of Egger's regression test showed evidence of publication bias, P-value ≤0.001. Because of the presence of publication bias, a trim and fill analysis were carried out to reduce the influence of studies that generate asymmetry in the funnel plot and to fill in imputed missing studies using a bias-corrected overall estimate. Accordingly, fifteen additional studies were fitted to the model, and a bias-corrected pooled estimate of blood specimen rejection in the random-effect model was found to be 0.29% (95%CI: 0.02, 0.57). Therefore, it can be concluded that publication bias has a significant impact on the overall effect estimate produced by the remaining studies (Fig. 5).
Fig. 4.
Funnel plot of studies included on the prevalence of blood specimen rejection rate.
Fig. 5.
Funnel plot showing publication bias after employing trim-fill analysis.
4.7. Causes of blood specimen rejection
As indicated in (Table 2) clotted specimen [32.23% (95%CI: 21.02, 43.43)] was the major cause of blood specimen rejection followed by hemolysis [22.87% (95%CI: 16.72, 29.02)]. However, insufficient volume of the specimen and labelling errors accounts the least causes of blood specimen rejection [22.81% (95%CI: 16.75, 28.87)] and [7.31% (95%CI: 6.12, 8.58)], respectively. Furthermore, the cause of blood specimen rejection was analyzed for each laboratory section. Accordingly, 40.24% (95%CI: 26.10–54.39) of samples in the hematology laboratory were rejected due to clotting, while 3.56% (95%CI: 0.84–6.28) of samples in the clinical chemistry section were rejected due to clotting. Hemolysis of blood samples was a major cause of specimen rejection in clinical chemistry laboratory section, accounting for 45.05% (95%CI: 21.97–68.14), whereas in the hematology section, it causes for 9.89% (95%CI: 7.57–12.21). Labelling error and insufficient volume of samples were approximately equal causes for sample rejection in both hematology and clinical chemistry laboratory (Table 3).
Table 2.
Meta-analysis results on the causes of blood specimen rejection.
| Causes of rejection | Number of studies | Prevalence (95% CI) | I2 | p-value |
|---|---|---|---|---|
| Clotted specimen | 24 | 32.23% (95%CI:21.02, 43.43) | 100% | ≤0.001 |
| Hemolysis | 26 | 22.87% (95%CI: 16.72, 29.02) | 100% | ≤0.001 |
| Insufficient volume | 25 | 22.81% (95%CI: 16.75, 28.87) | 99.9% | ≤0.001 |
| Labelling errors | 23 | 7.31% (95%CI: 6.12, 8.58) | 99.5% | ≤0.001 |
Abbreviation: CI; Confidence interval.
Table 3.
Cause of blood specimen rejection by laboratory section.
| Cause of rejection | Number of studies | Laboratory section | Prevalence (95% CI) | Heterogeneity |
|
|---|---|---|---|---|---|
| I2 (%) | P-value | ||||
| Clotting | 10 | Hematology | 40.24(26.10–54.39) | 99.8 | ≤0.001 |
| 4 | Clinical Chemistry | 3.56(0.84–6.28) | 98.3 | ≤0.001 | |
| 7 | Hematology and clinical chemistry | 36.48(21.85–51.12) | 99.9 | ≤0.001 | |
| 2 | Clinical chemistry, immunology and hematology | 30.86(5.17–56.04) | 99.0 | ≤0.001 | |
| 1 | Clinical chemistry and immunology | 39.87(35.96–43.78) | – | – | |
| Hemolysis | 8 | Hematology | 9.89(7.57–12.21) | 98.8 | ≤0.001 |
| 7 | Clinical Chemistry | 45.05(21.97–68.14) | 99.9 | ≤0.001 | |
| 8 | Hematology and clinical chemistry | 11.94(6.47–17.42) | 99.8 | ≤0.001 | |
| 2 | Clinical chemistry, immunology and hematology | 14.67(8.81–20.53) | 89.2 | 0.002 | |
| 1 | Clinical chemistry and immunology | 48.50(44.51–52.49) | – | – | |
| Insufficient volume | 7 | Hematology | 26.12(12.85–39.38) | 99.9 | ≤0.001 |
| 7 | Clinical Chemistry | 23.97(7.54–40.39) | 99.9 | ≤0.001 | |
| 8 | Hematology and clinical chemistry | 20.76(9.94–31.57) | 99.9 | ≤0.001 | |
| 2 | Clinical chemistry, immunology and hematology | 22.27(20.59–23.95) | 0.00 | 0.349 | |
| 1 | Clinical chemistry and immunology | 22.81(16.75–28.87) | – | – | |
| Labelling errors | 10 | Hematology | 5.70(4.27–7.13) | 96.9 | ≤0.001 |
| 6 | Clinical Chemistry | 8.89(5.65–12.13) | 98.2 | ≤0.001 | |
| 6 | Hematology and clinical chemistry | 8.17(6.49–9.85) | 99.5 | ≤0.001 | |
| 1 | Clinical chemistry and immunology | 1.66(0.64–2.58) | – | – | |
5. Discussion
Clinical laboratory sample analysis is essential in the provision of health care to hospital patients. It is estimated that laboratory results influence 60–70% of all major clinical decisions such as therapy, admission, or discharge [41]. Pre-analytical errors contribute to a number of patient safety risks. Improper sample collection may cause delay patient results to be delayed due to unnecessary specimen redraws and extended remedial and preventive actions. Sample rejection prevents sample analysis, which increases turnaround time (TAT) and cause delays in patient diagnosis and treatment [[40], [41], [42]].
This study found that the overall rate of blood specimen rejection in clinical laboratories was 1.99% (95% CI: 1.73, 2.25). This finding is consistent with studies conducted in Africa (2.0%) [43] and Saudi Arabia (2.07%) [44], and it is higher studies conducted in India (0.54%) [32], Turkey (0.65%) [6], and Brazil (0.62%) [39]. However, it was lower than studies done in India (10.58%) [23] and Turkey (5.97%) [45]. The difference in sample size, clinician and phlebotomist awareness, operational definition of laboratory errors, and laboratory quality requirements could be reasons for this variation.
Due to considerable heterogeneity (I2 = 100%, P ≤ 0.00) across the included papers, a subgroup analysis by WHO-region was performed. According to the meta-analysis results, the highest rate of blood specimen rejection was found in the South-east Asian region (3.19% (95%CI: 2.03, 4.35)) and African region [1.79% (95%CI: 1.43, 2.15)], while the lowest was found in the European region [1.32% (95%CI: 0.64, 2.00)] and American regions [0.55% (95%CI: 0.27, 0.82)]. The possible explanation for the high prevalence of specimen rejection rate in South-east Asian and African region might be due to the lack of trained phlebotomist for proper sample collection, inadequate infrastructures, increased patient flow or poor-quality management system and poor adherence to follow standard operating procedures. Standardization and monitoring of pre-analytical variables, establishing well-organized laboratories, adequate educational and technological trainings which results reduce operational costs and increased revenues of the laboratories is need [46,47]. Likewise, the subgroup analysis of this study on each laboratory section, the highest pooled prevalence blood specimen rejection was detected in clinical chemistry section (3.05% (95%CI: 1.74, 4.35), followed by the hematology section (1.22% (95%CI: 0.91, 1.53)). The possible reason for the variation could be attributed to the difference in the number of quality indicators, study design, sample size, and laboratory performance.
A trim and fill analysis were performed due to the presence of publication bias in order to reduce the effect of studies that induce asymmetry in the funnel plot and to fill in the imputed missing studies using a bias-corrected overall estimate. As a result, when an additional 15 missing studies are included, the pooled estimate of blood specimen rejection in the random-effect model falls from 1.99% to 0.29%. This indicates that publication bias has an effect on the overall effect estimate, which can affect the validity and generalization of conclusions [48].
This meta-analysis also aims at identifying the possible reasons of blood specimen rejection in clinical laboratory. The most frequent cause of specimen rejection was clotted specimen (32.23% (95%CI: 21.02, 43.43)). The result was comparable with studies conducted in China [22], USA [40], and Turkey [28] which reported clotting as the main cause of sample rejection. Clotting is a major cause of samples rejection in hematology laboratory (40.24% (95%CI: 26.10–54.39)), while it less common in clinical chemistry section (3.56% (95%CI: 0.84–6.28)). The finding is consistent with previous studies by Cakirca et al. [27], Goswami et al. [29], and Narang et al. [33]. The probably reason might be due to poor mixing after blood collection [29]. The Clinical Laboratory Standards Institute recommends that all diagnostic blood specimens collected in vacuum tubes are recommended to be inverted gently several times to maximize the contact between blood and additives following blood collection [49,50]. Clotting produce low red cell counts (RBC), aberrant red cell indices, low hematocrit, low white cell counts, and platelet count [51,52]. It also contributed to instrument probe aspiration and clogging, leading to service calls and downtime [53], which prolong TAT of the specimens processing and result reporting.
The second frequent reason for specimen rejection in this study was hemolysis, which is in agreement with the results reported in Brazil [7] and USA [40]. In line with previous studies [27,30], hemolysis of blood samples were a major cause rejection in clinical chemistry laboratory section. Because hemolysis is known to interfere with the measurement of several biochemical analytes such as lactate dehydrogenase, aspartate aminotransferase, potassium, and total bilirubin [54]. In vivo hemolysis occurs as a result of the premature death of RBCs due to antigen-antibody reactions, chemical reaction, toxins and poisonous substance, and mechanical destruction of RBC [[55], [56], [57]]. In vitro hemolysis could be due to pre-analytical errors like incorrect needle size, improper tube mixing, incorrect filling of tubes, excessive suction, prolonged tourniquet, extreme temperature, delayed processing, and prolonged storage [[58], [59], [60]].
This study found that the other cause of sample rejection was due to insufficient or inadequate volume of the specimen which accounts 22.81% (95%CI: 16.75, 28.87) of rejection. This finding was in line with single centered studies conducted in Malaysia [11], South Africa [15], and India [23]. Collection of an inadequate volume may also cause blood clotting. For the anticoagulant to perform the expected action, it is necessary that the proportion of blood/anticoagulant ratio is according to the tube manufacturers’ recommendations [39,61]. Studies shows that the incidence of insufficient volume is remarkably high in pediatric, neonatal, and oncology wards, in which peripheral vascular access is difficult [62,63]. Labelling errors (mislabeled and unlabeled specimens) is the less frequently reason for blood specimen rejection in this study. The result was comparable with previous studies done in South Africa and India [15,30]. This may occur at the time of collection where patients are misidentified, the use of illegible handwritten labels and mix-ups occurring before or after collection [64,65]. It can lead to delayed diagnosis, additional laboratory testing being ordered, or the patient being treated for the wrong medical condition.
This review used a comprehensive search strategy and PRISMA guideline was strictly followed during the review process. The limitation of this study was that only articles published in English language were included. Besides, the meta-analysis showed that there was statistical level of heterogeneity and publication bias which may potentially limit the conclusions of the study. All of the criteria for specimen rejection are not included in this study, only hemolysis, clotting, labelling error and insufficient volume were assessed which could potentially limit the study findings.
6. Conclusion and recommendation
In clinical laboratories, the overall prevalence of blood specimen rejection was significant. Clotted specimens, hemolysis, insufficient volume, and labelling errors were the top major reason for specimen rejection. Clotting and hemolysis of blood specimens was a major reason of sample rejection in hematology and clinical chemistry laboratory section, respectively. Specimen rejection has significant consequences including patient discomfort, unnecessary specimen redraws, and delay in diagnosis and treatment of patients. Therefore, targeted training for sample collectors and adherence to policies and procedures specific to specimen collection, transportation, and preparation is necessary. In addition, laboratories themselves should regularly review the specimen rejection rate and related influence factor and take effective actions.
Ethical approval
Not applicable.
Funding
There are no funding sources for this paper.
Author contribution
All authors involve in literature search, manuscript draft, review, statistical analysis, final approval, and quality assessment. The authors critically revised the paper and agreed to be accountable for all aspects of the work.
Consent for publication
Not applicable.
Declaration of competing interest
The authors declare that they have no competing interests.
Acknowledgments
We would like to acknowledge all the authors of the included studies in this review and meta-analysis.
Footnotes
Supplementary data to this article can be found online at https://doi.org/10.1016/j.plabm.2022.e00303.
Contributor Information
Solomon Getawa, Email: solomon.getawa@uog.edu.et.
Melak Aynalem, Email: melak.aynalem1234@gmail.com.
Mulugeta Melku, Email: mulugeta.melku@gmail.com.
Tiruneh Adane, Email: tirunehadane01@gmail.com.
Abbreviations
- TAT
Turnaround time,
- CI
Confidence interval
- RBC
Red blood cell
- USA
United States of America
Appendix A. Supplementary data
The following are the Supplementary data to this article:
Data availability
Data will be made available on request.
References
- 1.Abbas M., Mukinda F.K., Namane M. The effect of phlebotomy training on blood sample rejection and phlebotomy knowledge of primary health care providers in Cape Town: a quasi-experimental study. African journal of primary health care & family medicine. 2017;9(1):1–10. doi: 10.4102/phcfm.v9i1.1242. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Chawla R., Goswami B., Singh B., Chawla A., Gupta V.K., Mallika V. Evaluating laboratory performance with quality indicators. Lab. Med. 2010;41(5):297–300. [Google Scholar]
- 3.Jandial S., Gosai V. Sample rejection rate in clinical biochemistry laboratory of a tertiary care centre. Int J Res Med. 2017;5(4):127–131. [Google Scholar]
- 4.Homme C.P., Lima-Oliveira G., Volanski W., Lippi G., Picheth G., Guidi G.C. Pre-analytical phase management: a review of the procedures from patient preparation to laboratory analysis. Scand. J. Clin. Lab. Invest. 2017;77(3):153–163. doi: 10.1080/00365513.2017.1295317. [DOI] [PubMed] [Google Scholar]
- 5.Saurav Patra M., Mukherjee B., Das A.K. Pre-analytical errors in the clinical laboratory and how to minimize them. Int. J. Bioassays. 2013;2(3):551–553. [Google Scholar]
- 6.Atay A., Demir L., Cuhadar S., Saglam G., Unal H., Aksun S., et al. Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors. Biochem. Med. 2014;24(3):376–382. doi: 10.11613/BM.2014.040. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Guimarães A.C., Wolfart M., Brisolara M.L., Dani C. Causes of rejection of blood samples handled in the clinical laboratory of a University Hospital in Porto Alegre. Clin. Biochem. 2012;45(1–2):123–126. doi: 10.1016/j.clinbiochem.2011.10.009. [DOI] [PubMed] [Google Scholar]
- 8.Almatrafi A.A. Preanalytical errors: a major issue in medical laboratory. Acta Soc. Med. Scand. 2019;3:93–95. [Google Scholar]
- 9.Alavi N., Khan S.H., Saadia A., Naeem T. Challenges in preanalytical phase of laboratory medicine: rate of blood sample nonconformity in a tertiary care hospital. EJIFCC. 2020;31(1):21. [PMC free article] [PubMed] [Google Scholar]
- 10.Shiferaw M.B., Yismaw G., Getachew H. Specimen rejections among referred specimens through referral network to the Amhara Public Health Institute for laboratory testing, Bahir Dar, Ethiopia. BMC Res. Notes. 2018;11(1):1–6. doi: 10.1186/s13104-018-3891-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Kamal F., Saman W.A.W.M., Monir M.A., Rahmat M. Analysis of sample rejection and the impact on quality of care in patients in a single tertiary healthcare facility in Malaysia. Environment-Behaviour Proceedings Journal. 2020;5(13):175–181. [Google Scholar]
- 12.Mehrotra A., Srivastava K., Bais P. An evaluation of laboratory specimen rejection rate in a North Indian setting-a cross-sectional study. Iosr-Jdms. 2013;7(2):35–39. [Google Scholar]
- 13.Tesfaw H.M., Segaye A., Hassen F. Frequency of specimen rejection and Associated Factors at St. Paul's hospital millennium medical college, addis ababa Ethiopia. Journal of Multidisciplinary Research in Healthcare. 2015;2(1):1–16. [Google Scholar]
- 14.Karcher D.S., Lehman C.M. Clinical consequences of specimen rejection: a College of American Pathologists Q-Probes analysis of 78 clinical laboratories. Arch. Pathol. Lab Med. 2014;138(8):1003–1008. doi: 10.5858/arpa.2013-0331-CP. [DOI] [PubMed] [Google Scholar]
- 15.Jacobsz L.A., Zemlin A.E., Roos M.J., Erasmus R.T. Chemistry and haematology sample rejection and clinical impact in a tertiary laboratory in Cape Town. Clin. Chem. Lab. Med. 2011;49(12):2047–2050. doi: 10.1515/CCLM.2011.743. [DOI] [PubMed] [Google Scholar]
- 16.Moher D., Liberati A., Tetzlaff J., Altman D.G. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Int. J. Surg. 2010;8(5):336–341. doi: 10.1016/j.ijsu.2010.02.007. [DOI] [PubMed] [Google Scholar]
- 17.Munn Z., Moola S., Lisy K., Riitano D., Tufanaru C. Methodological guidance for systematic reviews of observational epidemiological studies reporting prevalence and cumulative incidence data. Int. J. Evid. Base. Healthc. 2015;13(3):147–153. doi: 10.1097/XEB.0000000000000054. [DOI] [PubMed] [Google Scholar]
- 18.Higgins J.P., Thompson S.G., Deeks J.J., Altman D.G. Measuring inconsistency in meta-analyses. BMJ. 2003;327(7414):557–560. doi: 10.1136/bmj.327.7414.557. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Egger M., Smith G.D., Schneider M., Minder C. Bias in meta-analysis detected by a simple, graphical test. BMJ. 1997;315(7109):629–634. doi: 10.1136/bmj.315.7109.629. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Sterne J.A., Egger M. Funnel plots for detecting bias in meta-analysis: guidelines on choice of axis. J. Clin. Epidemiol. 2001;54(10):1046–1055. doi: 10.1016/s0895-4356(01)00377-8. [DOI] [PubMed] [Google Scholar]
- 21.Ambachew S., Adane K., Worede A., Melak T., Asmelash D., Damtie S., et al. Errors in the total testing process in the clinical chemistry laboratory at the University of Gondar Hospital, Northwest Ethiopia. Ethiopian journal of health sciences. 2018;28(2):235–244. doi: 10.4314/ejhs.v28i2.15. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Ye Y., Wang W., Zhao H., He F., Zhong K., Yuan S., et al. Haematology specimen acceptability: a national survey in Chinese laboratories. Biochem. Med. 2018;28(3):420–429. doi: 10.11613/BM.2018.030704. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Bhutani N., Bhutani N. An analysis of preanalytical errors and turnaround time in emergency biochemistry laboratory in a tertiary care hospital in New Delhi. J. Evol. Med. Dent. Sci. 2020;9(13):1065–1069. [Google Scholar]
- 24.Ata'o m, Pusahai-Riman P. Rate of rejection of haematology samples in pathology department in port moresby general hospital: a retrospective study. Pacific journal of medical sciences. 2017;17(1) [Google Scholar]
- 25.Kadić D., Avdagić-Ismić A., Hasić S. The prevalence of pre-analytical errors in the laboratory of the Cantonal Hospital Zenica in Bosnia and Herzegovina. Med. Glas. 2019;16(1) doi: 10.17392/979-19. [DOI] [PubMed] [Google Scholar]
- 26.Yenice S., Maden C., Ozsen E., Gundogan S., Esin T., Bicakkiran S., et al. Study on the reasons for specimen rejection by the clinical chemistry laboratory. Clin. Biochem. 2009;4(42):330–331. [Google Scholar]
- 27.Cakirca G. The evaluation of error types and turnaround time of preanalytical phase in biochemistry and hematology laboratories. Iranian journal of pathology. 2018;13(2):173. [PMC free article] [PubMed] [Google Scholar]
- 28.Lay I.S., Pınar A., Akbıyık F. Classification of reasons for rejection of biological specimens based on pre-preanalytical processes to identify quality indicators at a university hospital clinical laboratory in Turkey. Clin. Biochem. 2014;47(12):1002–1005. doi: 10.1016/j.clinbiochem.2014.04.024. [DOI] [PubMed] [Google Scholar]
- 29.Goswami A.P., Roy S.S., Goswami N.N. Evaluation of specimen rejection rate in Haematology Laboratory. J Dent Med Sci. 2014;13(9):1–4. [Google Scholar]
- 30.Sushma B., Shrikant C. Study on “pre-analytical errors in a clinical biochemistry laboratory”: the hidden flaws in total testing. Biochem. Anal. Biochem. 2019;8(374) 2161-21009.19. [Google Scholar]
- 31.Arul P., Pushparaj M., Pandian K., Chennimalai L., Rajendran K., Selvaraj E., et al. Prevalence and types of preanalytical error in hematology laboratory of a tertiary care hospital in South India. J. Lab. Phys. 2018;10(2):237. doi: 10.4103/JLP.JLP_98_17. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Bhat V., Tiwari M., Chavan P., Kelkar R. Analysis of laboratory sample rejections in the pre-analytical stage at an oncology center. Clin. Chim. Acta. 2012;413(15–16):1203–1206. doi: 10.1016/j.cca.2012.03.024. [DOI] [PubMed] [Google Scholar]
- 33.Narang V., Kaur H., Selhi P.K., Sood N., Singh A. Preanalytical errors in hematology laboratory-an avoidable incompetence. Iranian journal of pathology. 2016;11(2):151. [PMC free article] [PubMed] [Google Scholar]
- 34.Abed R. Rate of hematology specimens rejection, association with area of collection and reason of rejection. Int. J. Biol. Med. Res. 2013;4(1):2902–2904. [Google Scholar]
- 35.Agarwal R., Chaturvedi S., Chhillar N., Goyal R., Pant I., Tripathi C.B. Role of intervention on laboratory performance: evaluation of quality indicators in a Tertiary Care Hospital. Indian J. Clin. Biochem. 2012;27(1):61–68. doi: 10.1007/s12291-011-0182-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Gupta V., Negi G., Harsh M., Chandra H., Agarwal A., Shrivastava V. Utility of sample rejection rate as a quality indicator in developing countries. The Journal of National Accreditation Board for Hospitals & Healthcare Providers. 2015;2(1):30. [Google Scholar]
- 37.Gaur K., Puri V., Shukla S., Sharma S., Suman S., Singh R. Finish before the start: analyzing preanalytical sample errors in a tertiary care hematology laboratory. Indian J. Pathol. Microbiol. 2020;63(3):435. doi: 10.4103/IJPM.IJPM_191_19. [DOI] [PubMed] [Google Scholar]
- 38.Cao L., Chen M., Phipps R.A., Del Guidice R.E., Handy B.C., Wagar E.A., et al. Causes and impact of specimen rejection in a clinical chemistry laboratory. Clin. Chim. Acta. 2016;458:154–158. doi: 10.1016/j.cca.2016.05.003. [DOI] [PubMed] [Google Scholar]
- 39.Coriolano N.L., Silva I.C.R., Lamounier T.A. Jornal Brasileiro de Patologia e Medicina Laboratorial; 2016. Analysis of the Frequency of Biological Sample Recollections as Quality Indicators in a Clinical Laboratory of Distrito Federal, Brazil. ahead):0. [Google Scholar]
- 40.Rooper L., Carter J., Hargrove J., Hoffmann S., Riedel S. Targeting rejection: analysis of specimen acceptability and rejection, and framework for identifying interventions in a single tertiary healthcare facility. J. Clin. Lab. Anal. 2017;31(3) doi: 10.1002/jcla.22060. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Forsman R.W. Why is the laboratory an afterthought for managed care organizations? Clin. Chem. 1996;42(5):813–816. [PubMed] [Google Scholar]
- 42.World Health Organization . World Health Organization; 2011. Laboratory Quality Management System: Handbook. [Google Scholar]
- 43.Asmelash D., Worede A., Teshome M. Extra-analytical clinical laboratory errors in Africa: a systematic review and meta-analysis. EJIFCC. 2020;31(3):208. [PMC free article] [PubMed] [Google Scholar]
- 44.Zaini R., Dahlawi H., Siddiqi A. Identification of the types and frequencies of pre-analytical errors in the clinical biochemistry laboratory: 1-year study at Hera'a General Hospital. Arch. Med. 2016;8(1) [Google Scholar]
- 45.Gunnur Dikmen Z., Pinar A., Akbiyik F. Specimen rejection in laboratory medicine: necessary for patient safety? Biochem. Med. 2015;25(3):377–385. doi: 10.11613/BM.2015.037. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Goswami B., Singh B., Chawla R., Mallika V. 2009. Evaluation of Errors in a Clinical Laboratory: a One-Year Experience. [DOI] [PubMed] [Google Scholar]
- 47.Lillo R., Salinas M., López Garrigós M., Naranjo Santana Y., Gutiérrez M., Marín M.D., et al. 2012. Reducing Preanalytical Laboratory Sample Errors through Educational and Technological Interventions. [PubMed] [Google Scholar]
- 48.Lin L., Chu H. Quantifying publication bias in meta‐analysis. Biometrics. 2018;74(3):785–794. doi: 10.1111/biom.12817. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Institute C.L.S. Clinical Laboratory Standards Institute; Wayne, PA: 2010. Procedures for the Handling and Processing of Blood Specimens for Common Laboratory Tests. CLSI H18-A4 Document. [Google Scholar]
- 50.Adcock D.M. CLSI; 2008. Collection, Transport, and Processing of Blood Specimes for Testing Plasma-Based Coagulation Assays and Molecular Hemostasis Assays: Approved Guideline. [Google Scholar]
- 51.Jones B.A., Meier F., Howanitz P.J. Complete blood count specimen acceptability. A College of American Pathologists Q-Probes study of 703 laboratories. Arch. Pathol. Lab Med. 1995;119(3):203–208. [PubMed] [Google Scholar]
- 52.Pewarchuk W., VanderBoom J., Blajchman M. Pseudopolycythemia, pseudothrombocytopenia, and pseudoleukopenia due to overfilling of blood collection vacuum tubes. Arch. Pathol. Lab Med. 1992;116(1):90–92. [PubMed] [Google Scholar]
- 53.Baumann N. QC notes at each phase of the analytical process are explored. Adv. Adm. Lab. 2011;20:37–41. [Google Scholar]
- 54.Koseoglu M., Hur A., Atay A., Cuhadar S. Effects of hemolysis interference on routine biochemistry parameters. Biochem. Med. 2011;21(1):79–85. doi: 10.11613/bm.2011.015. [DOI] [PubMed] [Google Scholar]
- 55.Guder W. Haemolysis as an influence and interference factor in clinical chemistry. J. Clin. Chem. Clin. Biochem. 1986;24(2):125–126. [PubMed] [Google Scholar]
- 56.Lippi G., Plebani M., Di Somma S., Cervellin G. Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories. Crit. Rev. Clin. Lab Sci. 2011;48(3):143–153. doi: 10.3109/10408363.2011.600228. [DOI] [PubMed] [Google Scholar]
- 57.Baek S.-W., Lee M.-W., Ryu H.-W., Lee K.-S., Song I.-C., Lee H.-J., et al. Clinical features and outcomes of autoimmune hemolytic anemia: a retrospective analysis of 32 cases. The Korean journal of hematology. 2011;46(2):111. doi: 10.5045/kjh.2011.46.2.111. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Tolan N.V., Kaleta E.J., Fang J.L., Colby C.E., Carey W.A., Karon B.S., et al. Neonatal intensive care unit quality initiative: identifying preanalytical variables contributing to specimen hemolysis and measuring the impact of evidence-based practice interventions. Am. J. Clin. Pathol. 2016;146(1):113–118. doi: 10.1093/ajcp/aqw086. [DOI] [PubMed] [Google Scholar]
- 59.Bush V., Mangan L. The hemolyzed specimen: causes, effects, and reduction. BD Vacutainer Syst Preanalytical Solut. 2003;2003:1–8. [Google Scholar]
- 60.Simundic A.-M., Nikolac N., Lippi G. Hemolysis detection and management of hemolyzed specimens. Biochem. Med. 2010;20(2):154–159. [Google Scholar]
- 61.CLSI Tubes . And Additives for Venous and Capillary Blood Specimen Collection. sixth ed. Clinical and Laboratory Standards Institute Wayne; PA: 2010. CLSI document GP39-A6. approved standard–. [Google Scholar]
- 62.Detaille T., Pirotte T., Veyckemans F. Vascular access in the neonate. Best Pract. Res. Clin. Anaesthesiol. 2010;24(3):403–418. doi: 10.1016/j.bpa.2010.02.017. [DOI] [PubMed] [Google Scholar]
- 63.Gallieni M., Pittiruti M., Biffi R. Vascular access in oncology patients. CA A Cancer J. Clin. 2008;58(6):323–346. doi: 10.3322/CA.2008.0015. [DOI] [PubMed] [Google Scholar]
- 64.Valenstein P.N., Raab S.S., Walsh M.K. Identification errors involving clinical laboratories: a College of American Pathologists Q-Probes study of patient and specimen identification errors at 120 institutions. Arch. Pathol. Lab Med. 2006;130(8):1106–1113. doi: 10.5858/2006-130-1106-IEICL. [DOI] [PubMed] [Google Scholar]
- 65.Wagar E.A., Stankovic A.K., Raab S., Nakhleh R.E., Walsh M.K. Specimen labeling errors: a Q-probes analysis of 147 clinical laboratories. Arch. Pathol. Lab Med. 2008;132(10):1617–1622. doi: 10.5858/2008-132-1617-SLEAQA. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
Data will be made available on request.