Skip to main content
. 2022 Dec 14;9:1009748. doi: 10.3389/fmed.2022.1009748

TABLE 6.

Semiquantitative clotting scores of the extracorporeal circuit and the AV-access site after dialysis.

Clotting score of the dialyzer n (%) Total UFH dose (IU/kg/sess) aPTT t4/0
Clean filter 15 (16) 119 ± 40 2.7 ± 1.8
Traces of coagulation in the filter 60 (64) 130 ± 64 3.7 ± 3.0
Intermediate state between previous and next score 19 (20) 126 ± 49 3.6 ± 2.3
Fully clotted ECC with interruption of the HD session 0 (0) NA NA

Clotting score of the venous chamber n (%) Total UFH dose (IU/kg/sess) aPTT t4/0

No visible clots in the drip chambers 63 (67) 131 ± 58 3.8 ± 2.8
Traces of coagulation in the drip chambers 27 (29) 123 ± 59 3.2 ± 2.5
Intermediate state between previous and next score 4 (4) 91 ± 29 1.7 ± 1.6
Fully clotted ECC with interruption of the HD session 0 (0) NA NA

Puncture site bleeding score (for AVF/AVG patients only) n (%) Total UFH dose (IU/kg/sess) aPTT t4/0

No bleeding 15 min after needle removal 29 (71) 90 ± 31 1.9 ± 1.3
Limited oozing 15 min after needle removal 9 (22) 82 ± 40 1.4 ± 0.5
Excessive bleeding 15 min after needle removal 3 (7) 101 ± 10 1.8 ± 1.0

ECC, extracorporeal circuit; IU, international units; sess, session.