Table 2.
The limit of detection (LOD) comparison for Hg2+ determination using the proposed AgNPs method with the previously reported method
| Method | Probe | LOD (mg/L) | References |
|---|---|---|---|
| ICP-MS | – | 2.10 × 10–5 | [39] |
| CV-AAS | – | 4.85 × 10–6 | [31] |
| Ligand spectrophotometry | Dithizone | 0.078 | [6] |
| Rhodamine B | 3.21 × 10–6 | [16] | |
| Nanomaterials spectrophotometry | AuNPs capped by histidine | 3.55 × 10–4 | [10] |
| AuNP using S. aromaticum extract | 0.002 | [8] | |
| AuNP capped by dithioerythritol | 4.81 × 10–5 | [17] | |
| AgNPs capped by carrageenan | 0.059 | [25] | |
| AgNPs using apple fruit extract | 0.017 | [11] | |
| AgNPs using A. bispores extract | 0.401 | [33] | |
| AgNPs-chitosan | 1.330 | [4] | |
| AgNPs using C. canephora fruit skin extract | 0.039 | Present work |