Skip to main content
. 2022 May 4;77(12):2356–2366. doi: 10.1093/gerona/glac102

Table 2.

Clinical and Laboratory Measures in the Losartan Treatment Group

Physical measurements (losartan treatment group) % Change, baseline to Visit 4 95% CI
p-value
Losartan 95% CI
p-value
EXP3174 95% CI
p-value
EXP3179 95% CI
p-value
Systolic blood pressure (mmHg) ↓ 10% 0.84, 0.96
.002
Diastolic blood pressure (mmHg) ↓ 7% 0.87, 1.00
.046
0.04 0.02, 0.06
<.001
2.3 0.6, 4.1
.008
Heart rate (beats per minute) ↑ 11% 1.02, 1.20
.01
Blood urea nitrogen (mg/dL) ↑ 15% 1.09, 1.22
≤.001
Chloride (mEq/L) ↑ 2% 1.00, 1.03
.02
0.01 0.003, 0.02
.003
CO2 (mmol/L) ↓ 5% 0.91, 0.99
.015
Knee srength (N) 0.01 0.002, 0.02
.007
3.2 1.7, 4.6
<.001
Frailty score −0.001 −0.001, −0.003
.005
−0.09 −0.16, −0.01
.02

Note: Upward arrows indicate positive correlations, downward arrows indicate negative correlations, and dashes indicate no correlation.