Skip to main content
. 2022 Dec 20;39:100565. doi: 10.1016/j.ctro.2022.100565

Table 2.

Summary of dose prediction performance using different networks. (Green and Red colors highlight the correct and wrong predictions, respectively).

Dose prescription
1 × 24 Gy
in record (48)
1 × 20–22 Gy
in record (48)
3 × 9 Gy
In record (32)
5 × 6 Gy
In record (24)
Model Type (CNN) 1P 2P 3P 1P 2P 3P 1P 2P 3P 1P 2P 3P
Predicted 1 × 24 Gy 29 34 44 12 10
7 2 0 0 2 0 0
Predicted 1 × 20–22 Gy 12 12 2 27 32 36 4 3 1 2 1 1
Predicted 3 × 9 Gy 3 2 2 6 6 3 16 19 25 6 6 4
Predicted 5 × 6 Gy 4 0 0 3 2 2 8 10 6 16 17 19



Model type Accuracy
mean (range)
Sensitivity
mean (range)
Specificity
mean (range)
AUC
1P 0.79 (0.74–0.85) 0.58 (0.50–0.67) 0.86 (0.83–0.88) 0.84
2P 0.84 (0.79–0.88) 0.67 (0.59–0.71) 0.89 (0.85–0.91) 0.88
3P 0.91 (0.88–0.93) 0.81 (0.75–0.92) 0.94 (0.91–0.96) 0.94