Table 2.
Summary of available preprocessing packages for mesoscale imaging data.
| Processing Phase (see 2.1.2) | Name of software package | ||||
|---|---|---|---|---|---|
| 1 | Input Triage | BIS-MID | MouseWOI | Mesoscale brain explorer | VOBI One |
| File conversion | Applied | - | - | - | |
| 2 | Preprocessing | Operations in orange are spatial and green are temporal | |||
| a | Brain mask creation | Manual | Manual | Manual | - |
| b | Smoothing | √ | √ | X | X |
| Motion correction | √ | X | √ | X | |
| Spatial down sampling | Factor of 2 | Factor of 2 | X | X | |
| Spatial detrending | X | √ | X | X | |
| Sharpening | X | X | √ | X | |
| Luminance correction | X | √ | X | √ | |
| Photobleach correction | √ | X | X | √ | |
| Heartbeat frequency estimation | X | X | X | √ | |
| Spectral denoising | X | X | X | √ | |
| Wavelength regression | √ | X | X | X | |
| Bandpass filtering | √ | √ | √ | X | |
| Temporal detrending | X | √ | X | √ | |
| Temporal down sampling | X | Factor of 2 | X | X | |
| Normalized fluorescence (dF/F) | √ | X | √ | √ | |
| Hemodynamic correction | N/A * | √ | X | N/A ** | |
| Common space alignment | √ | √ | X | X | |
| Global signal regression | √ | √ | X | X | |
| Band pass filtering | √ | √ | √ | X | |
| 3 | Quality control | ||||
| a | Framewise displacement | Output | - | Output | - |
| b | Brain mask | - | Output | - | - |
For dual-wavelength mesoscale imaging data, wavelength regression is a hemodynamic correction
Correction is performed for estimated heartbeat frequency