Skip to main content
. Author manuscript; available in PMC: 2023 Jan 3.
Published in final edited form as: Neuroimage. 2022 Nov 5;264:119735. doi: 10.1016/j.neuroimage.2022.119735

Table 2.

Summary of available preprocessing packages for mesoscale imaging data.

Processing Phase (see 2.1.2) Name of software package
1 Input Triage BIS-MID MouseWOI Mesoscale brain explorer VOBI One
File conversion Applied - - -
2 Preprocessing Operations in orange are spatial and green are temporal
a Brain mask creation Manual Manual Manual -
b Smoothing X X
Motion correction X X
Spatial down sampling Factor of 2 Factor of 2 X X
Spatial detrending X X X
Sharpening X X X
Luminance correction X X
Photobleach correction X X
Heartbeat frequency estimation X X X
Spectral denoising X X X
Wavelength regression X X X
Bandpass filtering X
Temporal detrending X X
Temporal down sampling X Factor of 2 X X
Normalized fluorescence (dF/F) X
Hemodynamic correction N/A * X N/A **
Common space alignment X X
Global signal regression X X
Band pass filtering X
3 Quality control
a Framewise displacement Output - Output -
b Brain mask - Output - -
*

For dual-wavelength mesoscale imaging data, wavelength regression is a hemodynamic correction

**

Correction is performed for estimated heartbeat frequency