Skip to main content
. 2023 Jan 3;3(1):e201. doi: 10.1002/deo2.201

TABLE 2.

Treatment results

B2 B3 p‐Value
Technical Success 92 68 0.321
Failure 0 1
Functional Success 77 64 0.935
Failure 15 5
Dilation None 7 5 0.000285
Mechanical 55 29
Balloon catheter 15 20
Electric catheter 15 15
Stent Plastic 74 40 0.0776
SEMS (full covered) 11 14
SEMS (partial covered) 7 15
Procedure time (min, mean, range) 35.2 (8–110) 47.0 (9–187) 0.00601
Adverse event None 80 55 0.306
Mediastinal emphysema 1
Sepsis 2 2
Ulceration 1
Bleeding 2 2
Peritonitis 2 4
Bile leakage 3 1
Pancreatitis 1
Stent slippage 1 2
Stent migration 1
Liver abscess 2

Abbreviation: SEMS, self‐expanding metallic stent.