Skip to main content
. 2022 Nov 7;61(1):155–177. doi: 10.1007/s11517-022-02697-8

Table 5.

Assessment of different fusion methods on CT/MR-PD images

Method and metrics DWT MPCNN CSR NSCT CSMCA GFS NSCT_SR NSCT_PCLP Proposed
EN 5.1882 4.5606 5.0707 5.2326 5.2264 5.0675 5.2382 5.3630 5.3986
MI 3.0102 2.8981 3.1521 3.2376 3.1540 3.1720 3.1314 2.9770 3.2543
QAB/F 0.3285 0.1949 0.4450 0.3787 0.4033 0.4591 0.3969 0.3244 0.4704
PSNR 62.8892 59.1924 62.9195 63.4793 63.2778 61.9589 63.4066 62.4729 63.9196
SD 72.5167 36.8359 66.2284 75.6873 70.2274 63.8462 76.9269 81.5905 85.0497
AG 8.5255 4.2299 7.3163 7.3904 6.6782 8.8754 7.3899 8.4993 9.4748
Time (sec) 0.3183 29.6324 51.4395 1.2437 327.855 0.2523 11.4953 2.5246 35.5117

The bold values indicate the best result of the evaluation criterion