Table 8.

Performance measures for ResNet-50 without optimization for X-ray images.

Category Accuracy (%) Specificity (%) Precision (%) Recall (%) F1-Score (%) FPR FNR Error Rate
Normal 97.58 97.56 97.52 97.47 97.49 0.0265 0.0365 0.0313
COVID-19 96.84 96.92 96.95 96.87 96.91 0.0244 0.0253 0.0242
Viral Pneumonia 96.87 97.35 97.27 96.35 96.81 0.0308 0.0313 0.0316