Table 9.

Performance measures for ResNet-50 after optimization for X-ray images.

Category Accuracy (%) Specificity (%) Precision (%) Recall (%) F1-Score (%) FPR FNR Error Rate
Normal 99.84 99.79 99.48 99.57 99.52 0.0021 0.0043 0.0016
COVID-19 98.98 98.88 98.78 98.88 98.83 0.0112 0.0112 0.0102