Skip to main content
. 2022 Dec 24;23(1):192. doi: 10.3390/s23010192

Table 2.

Acceleration data for the three axis during the six steps trials.

Device
Mean Acceleration No of Steps Trials Smartphone 1
(Mean ± SD)
Smartphone 2 (Mean ± SD) Smartphone 3
(Mean ± SD)
Vicon System
(Mean ± SD)
X axis 1 9 −0.0497 ± 0.0050 −0.0492 ± 0.0048 −0.0487 ± 0.0041 −0.0495 ± 0.0042
2 −0.0512 ± 0.0016 −0.0487 ± 0.0035 −0.0466 ± 0.0037 −0.0468 ± 0.0043
3 −0.0484 ± 0.0035 −0.0506 ± 0.0037 −0.0476 ± 0.0046 −0.0496 ± 0.0029
4 −0.0486 ± 0.0040 −0.0493 ± 0.0037 −0.0496 ± 0.0050 −0.0495 ± 0.0030
5 −0.0488 ± 0.0047 −0.0486 ± 0.0036 −0.0507 ± 0.0038 −0.0493 ± 0.0049
6 −0.0495 ± 0.0033 −0.0499 ± 0.0043 −0.0518 ± 0.0020 −0.0490 ± 0.0053
Total 54 −0.0494 ± 0.0038 −0.0494 ± 0.0038 −0.0492 ± 0.0042 −0.0489 ± 0.0041
Y axis 1 9 −0.0237 ± 0.0083 −0.0286 ± 0.0091 −0.0279 ± 0.0099 −0.0287 ± 0.0060
2 −0.0287 ± 0.0088 −0.0314 ± 0.0074 −0.0305 ± 0.0080 −0.0241 ± 0.0072
3 −0.0274 ± 0.0076 −0.0309 ± 0.0089 −0.0279 ± 0.0064 −0.0226 ± 0.0072
4 −0.0282 ± 0.0110 −0.0269 ± 0.0073 −0.0292 ± 0.0069 −0.0220 ± 0.0077
5 −0.0294 ± 0.0070 −0.0246 ± 0.0062 −0.0272 ± 0.0079 −0.0291 ± 0.0083
6 −0.0270 ± 0.0090 −0.0269 ± 0.0094 −0.0231 ± 0.0066 −0.0236 ± 0.0051
Total 54 −0.0274 ± 0.0085 −0.0282 ± 0.0081 −0.0276 ± 0.0077 −0.0250 ± 0.0073
Z axis 1 9 −0.0053 ± 0.0259 −0.0031 ± 0.0245 0.0176 ± 0.0274 0.0074 ± 0.0311
2 0.0017 ± 0.0351 0.0088 ± 0.0291 0.0186 ± 0.0199 0.0176 ± 0.0166
3 0.0066 ± 0.0249 0.0155 ± 0.0309 −0.0014 ± 0.0197 −0.0054 ± 0.0312
4 0.0073 ± 0.0268 0.0287 ± 0.0203 0.0051 ± 0.0299 0.0165 ± 0.0309
5 0.0070 ± 0.0270 0.0067 ± 0.0246 −0.0113 ± 0.0115 0.0124 ± 0.0240
6 0.0164 ± 0.0283 −0.0015 ± 0.0251 −0.0005 ± 0.0253 0.0068 ± 0.0281
Total 54 0.0056 ± 0.0276 0.0092 ± 0.0270 0.0047 ± 0.0245 0.0092 ± 0.0273