Figure 2.
Summary of the results of the investigation of the effect of the cell OD750 on the model reaction rate. (a) Progression curve determined for the 5 investigated OD750, including the determined standard deviation. (b) Specific activity and product formation rate determined for each OD750, calculated with the slope of the first 15 min of the progression curve. (c) Comparison of the progression curves for the experiments carried out in the coil reactor both at room temperature and at 30 °C, both at optimal operating conditions. (d) Comparison of the specific activities achieved at best reaction conditions for different reactor geometries. [a] The results in the batch and BCR were retrieved from Ref. [5]. For all figures, error bars correspond to standard deviations from at least three independent biological replicates.