Skip to main content
. 2022 Nov 25;32(11):e13163. doi: 10.1111/ina.13163

TABLE 2.

CADR for different fan configurations and test conditions at high fan setting, unless noted

Condition CADR (CFM) Device noise level (dbA) Power consumption (W) Initial cost ($) a Weekly operating cost ($) b

Baseline

Low fan speed

79.7 ± 3.1 35 58.8 ± 0.2 45.38 0.78

Baseline

Medium fan speed

96.9 ± 2.1 67.5 ± 0.6 45.38 0.89

Baseline

High fan speed

111.2 ± 1.3 55 77.1 ± 0.8 45.38 1.02
Corner 119.6 ± 4.4 78.4 ± 0.6 45.38 1.04
Smoke 4.31 ± 0.9 76.1 ± 0.6 45.38 1.00
Dust 22.9 ± 0.8 77.8 ± 0.3 45.38 1.02
Bungee 120.9 ± 11.9 63 77.8 ± 0.2 42.78 1.03
Outlet 121.3 ± 7.9 64 78.6 ± 0.3 45.38 1.04
MERV11‐1″ 63.6 ± 6.8 63 78.3 ± 0.6 43.65 1.03
MERV13‐4″ 247.9 ± 14.6 63 77.7 ± 0.3 72.81 1.03
Fan B 143.2 ± 8.2 75 104.8 ± 0.7 70.38 1.38
Fan C 124.3 ± 6.1 62 71.8 ± 0.4 39.38 0.95
Shroud 156.1 ± 3.6 62 77.6 ± 0.2 45.38 1.02
Wedge 263.1 ± 21.8 61 76.1 ± 0.4 54.78 1.01
CR box 400.9 ± 30.7 55 76.0 ± 1.1 73.59 1.00

Commercial

Turbo fan speed

118.9 ± 0.7 51 41.1 ± 0.2 123.05 0.54
a

Prices obtained from national retailers in April 2022, filter unit price derived from a pack of 6.

b

Prices estimated with the air cleaner being used for 8 h per day 7 days a week at an electricity cost of 23.58 ¢/kWh average price for CA in March 2022. 39 This does not include price of replacement filters.