Skip to main content
. 2022 Jun 11;18(1):248–263. doi: 10.1016/j.jds.2022.05.026

Table 3.

The stress values (MPa) of the TISP with a rigid connector in different bridge distances (12 mm, 14 mm, 16 mm, 18 mm, and 20 mm) models.

TS PDL 0.4 mm CM1 CR1+2 CM3 CR3 COR SPO IF IAB FS
R1 (12) 57.52 27.09 35.30 231.05 163.31 38.67 92.69 47.75 37.67 82.50 NA NA
R1 (14) 47.80 18.72 25.25 210.11 139.28 28.46 81.22 36.01 24.76 59.42 NA NA
R1 (16) 44.35 18.42 27.49 214.35 137.86 27.73 70.76 32.61 23.70 57.29 NA NA
R1 (18) 52.90 31.78 40.28 213.89 142.71 32.95 90.25 41.01 30.84 68.75 NA NA
R1 (20) 53.17 30.57 39.23 213.66 138.96 30.77 96.88 37.29 28.70 65.03 NA NA
R2 (12) 50.32 21.61 33.36 220.76 142.00 34.84 38.72 25.22 21.15 419.44 140.68 NA
R2 (14) 49.64 21.99 32.62 216.81 146.15 32.05 36.72 29.95 20.32 388.72 190.16 NA
R2 (16) 46.23 21.62 32.06 208.38 152.06 30.35 34.65 37.43 37.43 398.04 145.76 NA
R2 (18) 48.16 23.77 33.45 218.32 159.30 29.98 33.85 25.16 17.04 356.60 161.26 NA
R2 (20) 52.98 23.82 32.77 234.79 174.39 29.00 74.10 29.99 20.27 355.67 160.97 NA
R3 (12) 57.50 19.73 28.49 228.85 144.25 77.83 35.92 25.29 15.61 314.54 245.09 45.19
R3 (14) 55.52 21.54 30.75 222.48 144.30 72.29 37.11 25.70 20.26 306.27 202.44 38.15
R3 (16) 47.22 25.37 35.38 227.17 149.26 75.41 35.95 25.00 23.12 306.39 176.20 39.87
R3 (18) 51.98 22.17 30.67 219.33 148.59 72.87 34.04 23.88 17.50 293.70 176.19 39.83
R3 (20) 55.92 43.83 57.75 227.12 143.72 85.01 39.17 31.38 16.34 346.57 271.74 54.08

TISP: Tooth-implant supported prosthesis; R1: Rigid connector with 1-piece abutment; R2: Rigid connector with 2-piece abutment; R3: Rigid connector with 3-piece abutment; TS: Tooth solid; PDL: Periodontal ligament; 0.4 mm: 0.4 mm Cortical bone; CM1: Cement1; CR1+2: Crown1+2; CM3: Cement3; CR3: Crown3; COR: Cortical bone; SPO: Spongy bone; IF: Implant fixture; IAB: Implant abutment; FS: Fixture screw.