Table1.
Facility beamline | Beam parameters Photon energy, repetition rate, pulse length, photons per pulse, focus | Detector pixels, pixel size, frame rate, distance | Sample delivery options | Sample environ ment | Pump laser pulse duration, wavelength, timing | Remarks | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
keV | Hz | fs | ph/pulse | μm | 106 | μm2 | Hz | mm | fs | nm | fs | ||||
LCLS, Menlo Park, USA, 2009 | |||||||||||||||
MFX | 5 – 24 | 120 | 30 – 100 or <10 |
1·1012 or 1·1011 |
3×3 (2×2) | ePix10K-2.1M | SF-ROX with sample change robot MESH, GDVN, HVE, DoD, fixed targets |
90–278 K Ambient pressure Helium available, humidity controlled |
50 – 150 < 8ns |
410 – 2400 210 – 2200 |
δt0<200 spec. encod. | Protein Crystal Screening (PCS) beam time available Data analysis pipeline / support Screening beam time available at SSRL synchrotron with matching sample delivery options. Beamline website |
|||
2.1 | 100 × 100 | 120 | 50 – 1500 | ||||||||||||
Rayonix 340-XFEL | |||||||||||||||
59 | 44 × 44 177 × 177 |
2.5 30 |
70 – 1100 | ||||||||||||
CXI | 6 – 10.5 or 10.5 – 25 |
120 | 30 – 100 or <10 |
1·1012 or 1·1011 |
0.1 or 1 | Jungfrau | MESH, GDVN, HVE, fixed targets | Vacuum (10−5 Torr) Ambient pressure |
50 – 150 ns |
410 – 2400 200 – 266 |
δt0<200 | PCS available in parasitic mode Data analysis pipeline and support Beamline website |
|||
4 | 75 × 75 | 120 | 70 – 580 | ||||||||||||
SACLA, Sayo, Hyogo, Japan, 2011 | |||||||||||||||
BL3 | 4–20 | 30 (60) | <10 | 1011 | >1 | MPCCD | SF-ROX, fixed targets, GDVN, HVE226 and DoD84 (in DAPHNIS chamber) | 100K - RT Helium at ambient pressure |
30 | 200 – 2700 | δt0 <7 | Feasibility study beam time available. Data analysis pipeline and support Beamline details |
|||
4 | 50 × 50 | 60 | 50 – 150 | ||||||||||||
BL2 | 4–15 | 30 (60) | <10 | 1011 | >1 | MPCCD | SF-ROX, GDVN, HVE226 and DoD (in DAPHNIS chamber) | 100K - RT, Helium at ambient pressure |
5 ns | 210 - 2600 | Feasibility study beam time available. Data analysis pipeline and support Beamline details |
||||
4 | 50 × 50 | 60 | 50 – 150 | ||||||||||||
SwissFEL, Villigen, Switzerland, 2019 | |||||||||||||||
Alvra | 2 −12.4 | 100 | - | 4·1011 | 1.5 | Jungfrau | HVE, GDVN (user supplied) | RT Helium at 5·10−4 - 800 mbar |
50 | 240 – 2500 | - | Data analysis pipeline and support Beamline website |
|||
4 or 16 | 75 × 75 | 100 | 100 | ||||||||||||
EuXFEL, Schenefeld (near Hamburg), Germany, 2017 | |||||||||||||||
SPB/SFX | 6–15 | 1.1 MHz or 4.5 MHz |
~25 | 1.5·1012 | 3 or <0.4 |
AGIPD | GDVN, aerosol injection HVE, fixted target at lower repetition rate (10 Hz) |
Vacuum, 1·10−6 mbar typical, 1.10−4 mbar maximum Ambient pressure at low rep rate (second interaction region) |
4.5 MHZ | Protein screening beamtime available Data analysis pipeline and support: EXtra-xwiz automated pipeline in beta-testing. Extra-xwiz documentation Up-to-date parameters |
|||||
15, 50 or 300 | 370 – 420 | - | |||||||||||||
1 | 200 × 200 | 4.5 MHz | 129–329 | 1.1 MHz | |||||||||||
<100 | 420 – 2600 | - | |||||||||||||
4.5 MHz | |||||||||||||||
0.85 or 400 ps | 1030 | - | |||||||||||||
Up to 20 Hz | |||||||||||||||
3–7 ns | 210 – 2400 | - | |||||||||||||
PAL-XFEL, Pohang, Korea, 2017 | |||||||||||||||
NCISFX | 2.2 – 15 | 60 | 25 | 3·1010 (monochrom.) or 1·1012 (pink) |
5×5 or 2×2 |
Rayonix MX225-HS | GDVN and HVE33,227, fixed targets | RT He at ambient pressure |
40 7 ns (15Hz) |
800/400/266 1064/532/355/266 |
δt0 < 20 | Protein screening beamtime available Beamline website |
|||
33 | 156×156 234×234 |
30 60 |
100 ~ 1000 | ||||||||||||
Jungfrau | |||||||||||||||
4 | 75 × 75 | 60 | 100 ~ 1000 | - |