Ultrasonic variables of automatic speckle tracking and manual measurement between weaning-failure and weaning-success groups

Weaning-success
N = 50
Weaning-failure
N = 38
p value
Automatic measurement
Mean excursion, cm 1.5 ± 0.8 1.1 ± 0.6 0.0163
Max excursion, cm 1.6 ± 0.9 1.2 ± 0.6 0.0143
Min excursion, cm 1.3 ± 0.8 1.0 ± 0.6 0.0270
Manual measurement
Excursion, cm 0.9 ± 0.4 0.9 ± 0.7 0.6681
Automatic measurement
Max velocity, cm/s 1.2 ± 0.7 1.0 ± 0.6 0.1837
Min velocity, cm/s 0.9 ± 0.7 0.8 ± 0.5 0.2747
Mean velocity, cm/s 1.0 ± 0.7 0.9 ± 0.5 0.2437
Manual measurement
Velocity, cm/s 1.4 ± 0.7 1.4 ± 0.8 0.8011