Table 4.
3D Gamma passing rates (as percent) for varied gamma criteria. A gamma criteria consists of distance-to-agreement and dose difference parameters to quantify the agreement of voxelized dose between two dose fields. All plans have been recalculated using ground truth dose matrices applied to their respective optimized fluence maps (i.e. they are considered “deliverable” dose).
| Unmasked | Masked at 1% of GT Dmax | ||||||
|---|---|---|---|---|---|---|---|
| Patient | Comparison | 2mm/2% | 1mm/1% | 0.5mm/0.5% | 2mm/2% | 1mm/1% | 0.5mm/0.5% |
| #1 | GT / DeepMC | 98.94 | 97.29 | 95.67 | 88.00 | 69.48 | 51.28 |
| GT / Noisy | 96.18 | 94.93 | 94.00 | 57.49 | 43.58 | 33.29 | |
| #2 | GT / DeepMC | 98.49 | 95.90 | 93.08 | 88.63 | 69.08 | 47.86 |
| GT / Noisy | 96.17 | 93.23 | 90.97 | 71.26 | 49.21 | 32.18 | |
| #3 | GT / DeepMC | 97.31 | 91.85 | 85.09 | 91.49 | 74.24 | 52.86 |
| GT / Noisy | 87.29 | 80.79 | 76.06 | 60.60 | 40.42 | 25.77 | |