Average effective thermal conductivity coefficient of the building fasteners.

Fastener no Description Effective thermal conductivity coefficient
The average of all values in measurement series (W m−1 K−1)
Absolute standard uncertainty (W m−1 K−1) Relative combined standard uncertainty (%)
1 Stainless steel fastener, δf = 2 mm 3.97  ± 0.05 1.13
2 Stainless steel fastener, δf = 3 mm 4.85  ± 0.08 1.57
3 Stainless steel fastener, δf = 3 mm with 5 holes 4.26  ± 0.06 1.39
4 Aluminum alloy fastener, δf = 2.75 mm 15.68  ± 0.46 2.91
5 Aluminum alloy fastener, δf = 4 mm 21.04  ± 0.68 3.23