Table 3.
Average effective thermal conductivity coefficient of the building fasteners.
Fastener no | Description | Effective thermal conductivity coefficient The average of all values in measurement series (W m−1 K−1) |
Absolute standard uncertainty (W m−1 K−1) | Relative combined standard uncertainty (%) |
---|---|---|---|---|
1 | Stainless steel fastener, δf = 2 mm | 3.97 | ± 0.05 | 1.13 |
2 | Stainless steel fastener, δf = 3 mm | 4.85 | ± 0.08 | 1.57 |
3 | Stainless steel fastener, δf = 3 mm with 5 holes | 4.26 | ± 0.06 | 1.39 |
4 | Aluminum alloy fastener, δf = 2.75 mm | 15.68 | ± 0.46 | 2.91 |
5 | Aluminum alloy fastener, δf = 4 mm | 21.04 | ± 0.68 | 3.23 |