Skip to main content
. Author manuscript; available in PMC: 2024 Jan 15.
Published in final edited form as: Neuroscience. 2022 Nov 29;509:132–144. doi: 10.1016/j.neuroscience.2022.11.028

Table 3.

Summary of the descriptive statistics of the oxy-hemoglobin (Oxy-Hb) transient characterization parameters (negative amplitude (NAmp, μM), positive amplitude (PAmp, μM), total amplitude (Tamp, μM), duration (second), negative slope (Nslope, NAmp/second), and positive slope (Pslope, PAmp/second) are defined in Figure 3 and in the Analysis of Transients subsection). Both the experimental mean and standard deviation, as well as the estimated mean and standard error of the estimated mean from the mixed ANOVA model, are reported. The p values are from the mixed ANOVA model comparison of infarcted to non-infarcted tissue. PAmp and PSlope were associated with infarction.

Oxy-Hb NAmp PAmp TAmp Duration NSlope PSlope
INFARCTED Mean 55.46 25.58 60.29 236.64 1.51 0.24
Std. Deviation 38.94 17.70 42.23 122.94 1.12 0.21
Estimated Mean 54.33 27.70 57.84 239.61 1.44 0.25
Std. Error of Estimated Mean 5.19 7.99 6.35 14.66 0.15 0.17
NON-INFARCTED Mean 38.70 57.12 77.10 237.77 1.78 1.04
Std. Deviation 22.27 40.97 46.84 99.53 1.74 0.89
Estimated Mean 39.21 55.57 75.10 235.82 1.58 0.99
Std. Error of Estimated Mean 6.49 5.88 6.93 12.61 0.17 0.12
STATISTICS p- values 0.14 <0.001 0.07 0.85 0.52 <0.001