TABLE 2.
Details on monitoring.
| A | ||||
| All | ILR | Smartphone ECG | p | |
| N = 116 | N = 23 | N = 93 | ||
| Median time to first arrhythmia, days (IQR) | 92 (16–233) | 40 (15–681) | 102 (21–232) | 0.801 |
| Median monitoring time per patient, days (IQR) | 322 (148–428) | 567 (40–1217) | 317 (188–399) | 0.045 |
| B | ||||
| Details on first arrhythmia | ||||
| All | ILR | Smartphone | p | |
| N = 116 | N = 23 | N = 93 | ||
| Arrhythmia occured, N (%) | 33 (28) | 11 (48) | 22 (24) | 0.021 |
| Atrial fibrillation, N (%) | 16 (14) | 2 (9) | 14 (15) | 0.428 |
| Supraventricular tachycardia, N (%) | 14 (12) | 6 (26) | 8 (9) | 0.021 |
| Ventricular tachycardia, N (%) | 1 (1) | 1 (4) | 0 | 0.043 |
| Sinus node defect, N (%) | 2 (2) | 2 (9) | 0 | 0.004 |
| Atrioventricular block, N (%) | 0 | 0 | 0 | 1.000 |
N, number; IQR, interquartile ranges; ILR, implantable loop recorder. Bold values represent the significant values.