. 2023 Jan 6;13(1):101. doi: 10.3390/bios13010101

Table A2.

Comparison of performance of the selected semi-dry EEG electrode.

Electrode Contact Impedance Signal Quality Biocompatibility (Cell Viability) Ref.
Stationary Motion
Bristle-shaped semi-dry electrode 15 kΩ Correlation: >90% - - [59]
AgNWs/PVB/melamine sponge (AgPMS) <10 kΩ - - - [61]
Flexible multi-layer semi-dry electrode 23.89 ± 7.44 kΩ (Oz)
18.18 ± 7.51 kΩ (Fpz)
Correlation: 95.84% Correlation: 90.65% - [23]
CF-based conductive silicone sponge EEG electrodes 2.5 kΩ - - - [62]
Micro-seepage electrode 9.3 kΩ (NaCl);
13.5 kΩ (PBS);
- - - [37]
Polymer wick-based quasi-dry electrode 3–5 kΩ Correlation: 98.2 ± 2.1% Coherence: 97.3 ± 3.0% - - [66]
Passive electrode based on porous Ti <10 kΩ (NaCl) Correlation: 95.55%
Coherence: 95.2%
SNR: 24.4 dB
- - [63]
Polycarbonate polymer wick column shape <30 kΩ - - [67]
Porous ceramics column shape 44.4 ± 16.9 kΩ Correlation: 88.3−99.7% - - [45,64]
L2-ePt electrode 10.0 ± 6.03 kΩ Correlation: 94 ± 5.3% - - [65]
Quasi-dry electrode - Correlation: 65−97% - - [27]