Skip to main content
. 2023 Jan 5;9(1):e12844. doi: 10.1016/j.heliyon.2023.e12844

Table 5.

Percentage Recovery efficiencies for quality control SRM digests.

N = 12 SRM digests carried out during Filter analysis
Element
Mean
(SD)
Na 100.9 (12.4)
Mg 97.0 (11.2)
Al 101.5 (4.2)
K 92.6 (11.2)
Ca 98.5 (9.4)
Ti 85.3 (5.6)
V 102.8 (7.2)
aCr 63.2 (4.6)
Mn 99.4 (6.9)
Fe 100.8 (5.6)
aNi 92.2 (20.9)
Cu 95.0 (9.9)
Zn 97.9 (8.1)
As 107.3 (7.3)
Sr 91.1 (8.3)
Cd 100.4 (5.1)
Sb 98.9 (5.3)
Pb 99.8 (4.0)
a

Mean value obtained from 10 samples due to outlier values in 2 samples.