Skip to main content
. 2023 Jan 11;16(2):723. doi: 10.3390/ma16020723

Table 1.

Non-conformities identified during the period under review.

Number Type of Non-Compliance Percentage Share Cumulative Value Quality Control Method with the Highest Detection Rate Specification of the Type of Control
1 Presence of shrinkage cavities 25.1% 25.1% RTG KA
2 Presence of oxides 22.5% 47.6% UT KA
3 Presence of fissures 19.7% 67.3% RTG KA
4 Internal cracks 10.9% 78.2% ET KA
5 Dimensional discrepancies 5.0% 83.2% P KL
6 Edge splitting 4.3% 87.5% VT KA
7 Fogging 4.2% 91.7% VT KA
8 Misalignment 2.6% 94.3% P KL
9 Underfill 2.4% 96.7% VT KA
10 Scratches 2.0% 98.7% VT KA
11 Cracks 1.3% 100.0% ET KA