K = 10-fold results (after 20 epochs, in %): for specificity (Spec), sensitivity (Sen), precision (Pre), F1 score (Fsc), and recall (Rec).

Spec Sen Pre Fsc Rec
K1 Fake 99.34 100.00 98.31 99.98 99.15
Real 100.00 99.34 98.56 98.78 99.56
K2 Fake 97.26 100.00 96.55 98.25 100.00
Real 100.00 97.26 100.00 98.61 97.26
K3 Fake 100.00 100.00 100.00 99.12 99.34
Real 100.00 100.00 99.54 98.67 99.76
K4 Fake 99.50 100.00 98.12 99.34 99.89
Real 100.00 99.50 98.90 99.38 98.86
K5 Fake 100.00 100.00 100.00 100.00 100.00
Real 100.00 100.00 100.00 100.00 100.00
K6 Fake 96.25 100.00 100.00 98.09 96.25
Real 100.00 96.25 94.23 97.03 100.00
K7 Fake 96.10 99.25 100.00 99.20 97.34
Real 99.25 96.10 95.32 98.30 99.89
K8 Fake 100.00 100.00 100.00 100.00 100.00
Real 100.00 100.00 100.00 100.00 100.00
K9 Fake 95.71 100.00 100.00 97.81 95.71
Real 100.00 95.71 95.16 97.52 100
K10 Fake 100.00 100.00 100.00 100.00 100.00
Real 100.00 100.00 100.00 100.00 100.00
μ±σ Fake 98.41 ± 1.75 99.93 ± 0.23 99.23 ± 1.15 99.18 ± 0.81 98.77 ± 1.59
Real 99.93 ± 0.23 98.41 ± 1.75 98.17 ± 2.20 98.83 ± 0.98 99.53 ± 0.83