Figure 4

Clinical validation of the mpox LAMP using extracted DNA from fifteen biological samples (five crusts, nine pus, one serum), five healthy serum samples and two non-template controls (NTC). (A) Scatter plot of the Tp (time to positive) values of the fluorescent LAMP and the Ct values of the real-time qPCR assay on biological samples. (B) Concordance between the fluorescent LAMP assay and qPCR for clinical samples. (C) Clinical validation of the visual LAMP was visualized after incubation for 60 min by naked eye.