Skip to main content
. 2023 Jan 10;28(2):684. doi: 10.3390/molecules28020684

Table 1.

Comparison of reported pretreatment methods of PQ and DQ in biological samples.

Analytical Methods Analytes Matrix Pretreatment Methods Adsorbent/
Extractant
Recovery LODS Ref.
UPLC–HRMS PQ & DQ Human urine MSPE Fe3O4@SiO2@poly(4-VB) PQ: 86.7–104.3%
DQ: 100.3–109.9%
PQ: 0.12 μg/L
DQ: 0.14 μg/L
[33]
LC–MS/MS PQ & DQ Blood & urine Protein precipitation Acetonitrile PQ: Blood: 87.32–94.96%/urine: 88.93–108.36%
DQ: Blood: 80.28–91.54%/urine: 95.56–101.02%
PQ: 0.1 μg/mL
DQ: 0.05 μg/mL
[14]
HPLC–HRMS PQ & DQ Blood Protein precipitation Acetonitrile: water = 3:1 (v:v) PQ: 86–108%
DQ: 88–96%
PQ: 5 ng/mL
DQ: 10 ng/mL
[19]
HPLC–DAD PQ & DQ Human plasma SPE 2 mL of ammonium formate, 2 mL of methanol, and 1 mL of a mixture solution of acetonitrile, ethyl acetate, and formic acid (4:4:2, v/v/v) PQ: 95.38–103.97%
DQ: 94.79–98.40%
0.01 μg/mL [24]
HPLC PQ & DQ Plasma & urine MDSPE CoFe2O4@SiO2 MNPs 87.5–98.7% PQ: 4.5 μg/L
DQ: 4.3 μg/L
[35]
HPLC–UV PQ Biological samples LLME Mixture of triethylamine and water 90.0–92.3% 0.2 μg/L [30]
HPLC–MS PQ Urine DSPE magnetic single-walled carbon nanotubes 92.89–108.9% 0.94 μg/L [34]
GC–MS PQ Plasma & urine HS-SPME Polydimethylsiloxane fiber Plasma: 94.00–99.85%
Urine: 95.00–100.34%
0.01 μg/mL [29]
UPLC–HRMS PQ Plasma & urine Protein precipitation Acetonitrile Plasma: 98.54–100.90%
Urine: 93.51–99.45%
Urine: 0.1 ng/Ml
Plasma: 0.3 ng/mL
[13]
GC–MS PQ & DQ Serum & urine Monolithic spin column extraction 0.2 mL of a mixture of chloroform and methanol (9:1 v/v) (MonoSpin® C18 extraction column) 51.3–106.1% PQ: 0.1 μg/mL
DQ: 0.025 μg/mL
[26]
HPLC–MS PQ & DQ Human urine SPE 1 mL of 5% methanol in deionized water (v/v) & 10% formic acid in acetonitrile (v/v) (Strata-X-CW 33 μm polymeric 3 mL weak cation cartridges) PQ: 83.4–85.5%
DQ: 77.7–94.2%
1 ng/mL [27]
UV-Vis Spectrometry PQ Plasma & urine MSPE Fe3O4@SiO2 NPs Plasma: 93.6–102.4%
Urine: 92.9–103.5%
12.2 μg/L [36]
UPLC–HRMS PQ human urine MSPE Amphiphilic carboxyl-functionalized magnetic polymer microspheres (Amphiphilic-MPs-COOH) 84.5–103% 0.1–1.6 μg/L [32]
LC–MS PQ Tissue Whirling agitated single-drop microextraction 1-dodecanol >91.21% 4.81 ng/g [31]
HPLC–UV PQ Human plasma protein precipitation with organic solvent backwashing Acetonitrile and methylene chloride 91.9% 0.01 μg/mL [21]
HPLC–UV PQ The whole blood Protein precipitation with hydrochloric acid Acetonitrile 87.9–106.7% 0.026 μg/mL [18]
HPLC–UV PQ Human plasma Protein precipitation Trichloroacetic acid-methanol (1:9) n.d. n.d. [17]

n.d.: not found; LODS: Limits of Detection.