Skip to main content
. 2023 Jan 21;13:1190. doi: 10.1038/s41598-023-28501-7

Table 3.

The experimental results of the hydro-mining effectiveness in terms of the depth (in cm) of the mined coal face spot.

Nozzle outlet diameter (mm) Operating time (s) Distance from the sidewall (m)
0.00 (m) 0.05 (m) 0.10 (m)
2.5 60 14 9 8
120 18 11 10
180 19 12 10
2.1 60 12 10 8
120 16 11 10
180 16 12 10