TABLE 2.
Main optical coherence tomography (OCT) parameters.
| SD-OCT parameters | Mean ± SD | Comparison between groups | p-values between groups post-hoc test with ANOVA | ||
| Central retinal thickness (μm) | Controls | 278.1 ± 23.9 | Controls | Group 1 | 0.603 |
| Group 1 | 294.1 ± 74.1 | Controls | Group 2 | 1.000 | |
| Group 2 | 270.1 ± 40.4 | Group 1 | Group 2 | 0.279 | |
| Mean peripapillary RNFL thickness (μm) | Controls | 83.3 ± 7.5 | Controls | Group 1 | 0.776 |
| Group 1 | 80.7 ± 9.1 | Controls | Group 2 | 0.683 | |
| Group 2 | 86.0 ± 8.6 | Group 1 | Group 2 | 0.136 | |
| Mean macular GCC thickness in central 3 mm (μm) | Controls | 99.3 ± 7.8 | Controls | Group 1 | 1 |
| Group 1 | 97.7 ± 9.9 | Controls | Group 2 | 0.190 | |
| Group 2 | 103.8 ± 9.5 | Group 1 | Group 2 | 0.093 | |