Skip to main content
. 2022 Oct 29;17(6):594–611. doi: 10.4103/1735-5362.359428

Table 5.

Intra and inter-day variations of the HPLC method for determination of insulin and pramlintide in the release medium

Insulin
Pramlintide
Concentration (μg/mL) Intra-day precision and accuracy
Inter-day precision and accuracy
Intra-day precision and accuracy
Inter-day precision and accuracy
Mean SD CV (%) Error (%) Mean SD CV (%) Error (%) Concentration (μg/mL) Mean SD CV (%) Error (%) Mean SD CV (%) Error (%)
30 26.89 0.43 1.6 10.35 27.66 0.27 1.00 7.80 1.5 1.64 0.01 0.92 9.33 1.62 0.008 0.51 8.00
60 57.82 0.01 0.02 3.63 57.62 0.05 0.10 3.96 2 2.43 0.07 3.15 21.5 2.36 0.07 2.24 18.00
105 106.80 0.07 0.07 1.71 105.10 0.54 0.52 0.09 3.5 3.27 0.09 3.02 6.57 3.20 0.099 3.08 8.57
150 147.06 3.6 2.5 1.96 153.57 3.36 2.19 2.38 5 4.65 0.08 1.74 7.00 4.59 0.08 1.78 8.20
195 204.01 6.21 3.04 4.60 204.99 5.46 2.56 5.12 6.5 6.42 0.11 1.71 1.23 6.39 0.15 2.39 1.69
240 242.80 4.9 2.03 1.16 243.56 6.09 2.32 1.48 8 8.23 0.11 1.43 2.87 8.27 0.15 1.88 3.37
300 297.76 3.03 1.01 0.74 299.18 3.30 1.10 0.27 10 9 85 0.07 0.73 1.50 9.92 0.07 0.72 0.80
360 356.02 0.24 0.06 1.11 356.15 5.69 1.60 1.07 12 12.18 0.004 0.04 1.50 12.11 0.10 0.90 0.91

SD, standard deviation; CV, coefficient of variation.