Skip to main content
. 2022 Nov 8;44(3):1094–1104. doi: 10.1002/hbm.26141

TABLE 4.

The results of classification in three frequency bands

Frequency bands (Hz) AUC Accuracy Precision Recall
Mean (±SD) Mean (±SD) Mean (±SD) Mean (±SD)
Conventional frequency band 0.804 (±0.0183) 73.39 (±2.83) 73.55 (±2.85) 73.06 (±2.94)
Slow‐4 frequency band 0.639 (±0.0204) 60.03 (±2.38) 59.89 (±2.34) 60.70 (±2.57)
Slow‐5 frequency band 0.811 (±0.0242) 74.73 (±2.78) 74.58 (±2.84) 75.05 (±2.77)

Note: The mean and SD values of the accuracy, precision, and recall metrics were reported as percentages (%), whereas the AUC was reported as decimals. Conventional frequency band: 0.01–0.08 Hz; Slow‐4 frequency band: 0.027–0.073 Hz; Slow‐5 frequency band: 0.01–0.027 Hz.

Abbreviations: AUC, area under the receiver operating characteristic curve; SD, standard deviation.