Skip to main content
. 2022 Dec 9:e14049. Online ahead of print. doi: 10.1002/ep.14049

TABLE 5.

HOMER‐pro results for PV/diesel HES

CS6X‐325P (kW) CAT‐500 (kW) CAT‐250 (kW) Inverter (kW) Net present cost ($) CoE ($) Operating cost ($/yr) Initial capital cost ($) Renewable fraction (%) System fuel consumption (m3/yr)
150 500 250 150 7,103,314 0.38 534,731 190,577 16.59 357
500 250 8,061,773 0.43 617,232 82,500 413
150 500 100 8,741,314 0.47 663,822 159,744 5.36 433
500 9,297,429 0.50 714,556 60,000 468