Skip to main content
. 2022 Dec 9:e14049. Online ahead of print. doi: 10.1002/ep.14049

TABLE 6.

HOMER‐Pro simulation output for PV/wind/diesel generators HES

PV (kW) Wind converter (kW) Diesel generator 500 (kW) Diesel generator 250 (kW) Inverter 30 (kW) Cost/CoE ($/kWh) System/total fuel (m3/yr) Cost/operating cost ($/yr) Cost/initial capital ($) Cost/NPC ($) System/Ren Frac (%) System/total fuel (L/yr)
150 8 500 250 150 0.348 298 462603.5 510,576 6,490,890 33.6 297,842.7
150 500 250 150 0.38 357 534530.5 190,576 7,100,728 16.6 357,088.3
150 4 500 100 0.46 413 642714.1 319,742.7 8,628,440 11.0 413,403
150 500 100 0.47 433 663688.7 159,742.7 8,739,589 5.3 433,109.2