Skip to main content
. 2023 Jan 17;9:1. doi: 10.1051/sicotj/2022050

Table 2.

Intra and postoperative complications, and postoperative functional outcomes at the last follow-up.

Patients (n = 170)
Surgical revision 8 (4.7%)
 Including implant removal 5 (2.9%)
  cup 3 (1.8%)
  femoral stem 2 (1.2%)
Major complication
 Dislocation 0
 Intra-prosthetic dislocation 0
 Early acute infection–Chronic infection 2 (1.2%)
 Acetabular cup loosening
  septic 1 (0.6%)
  aseptic 0
 Femoral loosening (1.2%)
  septic 0
  aseptic 2 (1.2%)
 Post-operative peri-prosthetic fracture 1 (0.6%)
  Acetabular side 0
  Femoral side 1 (0.6%)
Minor complication
 Ilio-psoas impingement 0
 Symptomatic came effect 0
 Medius gluteus tendinitis 2 (1.2%)
 Per-operative femoral fracture 1 (0.6%)
 Greater trochanter fractures 3 (1.8%)
 Femoral wrong way 0
HHS 96 ± 4.5 [50–100]
Repartition of HHS
 Excellent (≥90) 153 (90%)
 Good (80–89) 13 (7.6%)
 Fair (70–79) 2 (1.2%)
 Poor (<70) 2 (1.2%)

HHS: harris hip score, DAIR = debridement, antibiotics and implant retention.