Table 5.
Results of the mixed-effects analyses testing whether the three outcomes of speech recognition development vary between the first and second implanted ears of children with sequential bilateral implantations.
Parameter | Estimate (β) | SE | t | p |
---|---|---|---|---|
Slope | ||||
Intercept | 5.75 | 1.65 | 3.84 | .002 |
Ear implanted | −0.66 | 2.31 | −0.28 | .78 |
Time between activation and plateau onset | ||||
Intercept | 6.58 | 0.98 | 6.74 | .0000 |
Ear implanted | −3.66 | 1.38 | −2.65 | .01* |
Score at plateau | ||||
Intercept | 19.90 | 0.22 | 89.62 | .000 |
Ear implanted | −0.90 | 0.29 | −3.15 | .004** |
Note. Statistically significant p values are in bold font.
Significant differences are represented with p values < .05.
Significant differences are represented with p values < .01.