Skip to main content
. 2021 Oct 8;277(3):e545–e551. doi: 10.1097/SLA.0000000000005239

Table 4.

Comparison of Postoperative Manometric Characteristics of Patients With a Smaller Sized LINX Device to Those With a Larger Device

Smaller Size Devices (<15 Magnetic Beads) Larger Size Devices (≥ 15 Magnetic Beads) P Value
LES overall length (cm) 2.9 (2.6–3.1) 2.7 (2.3-3.5) 0.851
LES intraabdominal length (cm) 1.3 (1.0, 1.5) 1.2 (0.3-1.9) 0.585
LES resting pressure, (mmHg) 31.6 (23.7–38.3) 25.9 (18.4–34.7) 0.209
Integrated relaxation pressure (IRP), (mmHg) 14.7 (11.6–18.1) 12.0 (8.9–14.2) 0.005
Distal contraction amplitude, (mmHg) 106.6 (78.4–144.3) 77.6 (59.1–109.2) 0.003
Distal contractile integral (DCI), (mmHg s cm) 2757 (1466–3894) 1720 (948–2929.0) 0.023
Intact peristalsis (%) 100 (90–100) 100 (80–100) 0.239
Incomplete bolus clearance (%) 0 (0–20) 10 (0–50) 0.146