Table 29:
Volume of Thrombolytic Infusion With Mechanical Thrombectomy Use in Acute and Subacute DVT in Randomized Controlled Trials
| Results | ||||
|---|---|---|---|---|
| Author, year | Outcome measurement | MT | Comparator | P value |
| PMT (AngioJet) | ||||
| ATTRACT trial90 (PMT vs. infusion first rtPA group) |
Median rtPA total dose | 21 mg (IQR: 12-28) | 21 mg (IQR: 18-26) | NS |
| Vacuum Aspiration (Indigo) | ||||
| No randomized studies met our inclusion criteria for this MT device | ||||
| Rotational (Rotarex or Cleaner) | ||||
| No randomized controlled trials met our inclusion criteria for this MT device | ||||
| Ultrasound Assisted (EKOS) | ||||
| We did not identify any randomized studies that reported on this outcome of interest | ||||
Abbreviations: ATTRACT, Acute Venous Thrombosis: Thrombus Removal with Adjunctive Catheter-Directed Thrombolysis; DVT, deep vein thrombosis; IQR, interquartile range; MT, mechanical thrombectomy; NS, not significant; PMT, pharmacomechanical thrombectomy.