Skip to main content
. 2023 Jan 24;13:1108142. doi: 10.3389/fonc.2023.1108142

Table 4.

Comparison of the dosimetric parameters (mean ± standard)of PTV and OARs.

Parameters VMATFFF (range) VMATFF (range) p
PTV D90 (Gy) 50.0 ± 0.21 (50.0-50.12) 50.0 ± 0.21 (50.0-50.13) 0.35
D2 (Gy) 55.30 ± 0.45 (54.52-56.42) 55.90 ± 0.50 (54.68-57.52) <0.001
CR 0.85 ± 0.02 (0.80-0.95) 0.86 ± 0.02 (0.79-0.92) 0.21
CI 0.78 ± 0.06 (0.62-0.91) 0.78 ± 0.07 (0.63-0.92) 0.15
R50% 4.88 ± 0.61 (3.29-6.72) 4.98 ± 0.64 (3.96-6.88) <0.001
GI 5.21 ± 0.73 (3.52-6.64) 5.33 ± 0.78 (3.55-6.91) <0.001
Spinal cord Dmax(Gy) 7.29 ± 4.37 (1.52-26.46) 7.44 ± 4.42 (1.63-26.55) <0.001
D0.25cc(Gy) 6.60 ± 3.85 (1.23-22.7) 6.81 ± 3.93 (1.3-22.75) <0.001
D0.5cc (Gy) 6.37 ± 3.66 (1.05-21.62) 6.60 ± 3.88 (1.1-21.56) <0.001
Esophagus Dmax(Gy) 6.95 ± 4.43 (0.04-24.72) 7.08 ± 4.39 (0.05-23.94) 0.011
D5cc (Gy) 3.71 ± 2.67 (0.37-16.13) 3.81 ± 2.72 (0.44-15.74) <0.001
Trachea Dmax(Gy) 5.12 ± 5.37 (0.03-23.16) 5.20 ± 5.37 (0.03-23.77) 0.13
D4cc(Gy) 3.11 ± 3.44 (0.01-13.81) 3.06 ± 3.44 (0.02-13.95) 0.25
Lung D1000cc (Gy) 1.21 ± 0.66 (0.08-4.10) 1.34 ± 0.93 (0.08-5.22) <0.001
D1500cc (Gy) 0.51 ± 0.37 (0.05-2.44) 0.55 ± 0.40 (0.05-2.70) <0.001
MLD(Gy) 2.39 ± 0.78 (0.61-4.59) 2.47 ± 0.80 (0.63-4.68) <0.001
V5(%) 12.10 ± 3.89 (2.11-24.15) 13.04 ± 3.90 (2.42-24.35) <0.001
V10(%) 6.69 ± 2.47 (1.12-13.97) 7.02 ± 2.42 (1.21-14.86) 0.013
V20(%) 3.01 ± 1.39 (0.14-6.96) 3.07 ± 1.35 (0.14-7.27) 0.016
Heart D1500cc (Gy) 5.48 ± 5.0 (0.06-36.48) 5.61 ± 5.05 (0.05-36.13) <0.001