Filtering efficiency of N95 FFRs against PM10.

S. N. N95 FFRs Without filtration (μg/m3) With filtration (μg/m3) TIL (%) Efficiency (%)
1. N95 (i) 60.32 ± 4.46 17.97 ± 3.27 30 70
2. N95 (ii) 5.34 ± 1.67 1.61 ± 1.81 30 70
3. N95 (iii) 131.7 ± 24.12 33.31 ± 26.74 25 75
4. NIOSH respirator 115.8 ± 19.43 34.63 ± 16.59 30 70